Field Settings for FTX, FVXS Series
SiUS091601EA
207
Part 7 Trial Operation and Field Settings
Caution
4.2 When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different address.
FTX09/12/15NMV
JU
1. Remove the battery cover of the remote controller.
2. Cut the address jumper.
3. Press the center of
TEMP
button and
OFF
switch on the remote controller at the same time.
4. Select
A
(address setting) with
TEMP
or
TEMP
button.
5. Press
FAN
button to enter the address setting mode.
The indoor unit operation lamp blinks for 1 minute.
6. Press indoor unit
ON/OFF
switch while the operation lamp is blinking.
7. Press
FAN
button on the remote controller for 5 seconds to return to the normal mode.
Replace the remote controller if you cut a jumper unintentionally
.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Wireless Remote Controller
R7000282
R7000281
Indoor Unit
R7000283
Address
EXIST
Jumper
CUT
1
2
Jumper
ON/OFF
OPERATION lamp
Indoor unit
ON/OFF
switch
Summary of Contents for FTX-N Series
Page 18: ...SiUS091601EA 13 Part 2 Specifications 1 Specifications 14 Part 2 Specifications...
Page 198: ...Check SiUS091601EA 193 Part 6 Service Diagnosis 18 24 class R24538 1 2 3 4 Multimeter...
Page 201: ...SiUS091601EA Check Part 6 Service Diagnosis 196 18 24 class R24539 DC DC W V U...
Page 229: ...SiUS091601EA Piping Diagrams Part 8 Appendix 224 RXL15QMVJU RXL18UMVJU 3D100007 3D123368...