Removal Procedure
9. Fan Guards / Vertical Blade ASSYs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the fan guards.
The fan guards are not
marked for difference
between right, center and
left.
1
2
3
Remove the sealing
material.
Unfasten the 2 hooks at
the bottom and remove
the fan guard.
Remove the other fan
guards in the same
way.
When reassembling, fit the
fan guard to the 2
projections at the top and
fasten the 2 hooks at the
bottom.
2. Remove the vertical blade
ASSYs.
Each vertical blade ASSY
has 5 fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right, center and
left.
1
Unfasten the upper 2
hooks.
2
3
4
Unfasten the 3 hooks at
the shaft mounting part
by pressing them with a
flat screwdriver.
Remove the vertical
blade ASSY.
Remove the other
vertical blade ASSYs in
the same way.
Hook
Sealing material
Fan guard
(R21536)
Projection
(R21537)
Hook
Vertical blade ASSY
(R21538)
Hook
(R21539)