background image

REMOVAL

PROCEDURE

S E R V I C E   M A N U A L

Indoor Unit

Inverter

Wall Mounted Type

9000/12000/18000 Btu/h Class

Si041417EA

Summary of Contents for FTH09P5VL

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Inverter Wall Mounted Type 9000 12000 18000 Btu h Class Si041417EA...

Page 2: ...Service Manual Removal Procedure Indoor Unit zCooling Only FTK09P5VL FTK12P5VL FTK18P5VL zHeat Pump FTH09P5VL FTH12P5VL FTH18P5VL FTX09N5VL FTX12N5VL FTX18N5VL...

Page 3: ...ters Front Panel 2 2 Front Grille 3 3 Horizontal Blade 4 4 Electrical Box 5 5 PCBs Swing Motor 9 6 Indoor Heat Exchanger 12 7 Fan Rotor Fan Motor 14 8 Fan Guards Vertical Blade ASSYs 16 Note The illus...

Page 4: ...inserting it along the guides Insert the air filter with the FRONT mark faced up Be sure to insert the 2 lower hooks when installing the air filter 1 2 Open the front panel Unfasten the 2 hooks and pu...

Page 5: ...tep Procedure Points 1 Remove the 2 screws of the front grille 2 3 Unfasten the 3 hooks at the top Pull out the upper part of the front grille lift up the lower part and then remove the front grille T...

Page 6: ...bending the horizontal blade slightly Installation procedure 1 Fit the right shaft of the horizontal blade first Make sure to rotate the horizontal blade so the shaft fits in the correct position 2 Fi...

Page 7: ...screw and then the wire fixture Remove the 4 screws of the terminal board and disconnect the connecting wire 2 Remove the electrical box When reassembling be sure to insert the earth ground wires in t...

Page 8: ...he top of the electrical box When reassembling be sure to insert the thermistor harness in the back slit and pass it below the pipes of the heat exchanger ASSY as shown in the picture 5 Unfasten the 4...

Page 9: ...S200 Release the harnesses from the 4 hooks S200 fan motor 8 9 Disconnect the connector S6 Release the harnesses from the 4 hooks S6 swing motor 10 Remove the screw of the electrical box Step Procedu...

Page 10: ...t the electrical box upward and remove it When reassembling make sure the hook is securely fastened When reassembling make sure that the 2 hooks are securely fastened to the bottom frame Step Procedur...

Page 11: ...embling work Step Procedure Points 1 Remove the control PCB 1 Disconnect all the 4 terminals 2 Release the wires from the 3 hooks 3 4 Remove the connector S26 Unfasten the 4 hooks and remove the contr...

Page 12: ...he 4 projections 2 Remove the display PCB 1 Unfasten the 3 hooks of the display PCB ASSY 2 Release the harnesses of the display PCB ASSY from the 2 hooks Step Procedure Points Projection R24261 Hook D...

Page 13: ...edure 11 3 4 Turn over the display PCB ASSY Unfasten the 3 hooks and remove the display PCB 3 Remove the swing motor 1 Remove the screw and then the swing motor Step Procedure Points Hook Display PCB...

Page 14: ...he spot of leaking then collect all refrigerant from the unit After conducting vacuum drying recharge proper amount of refrigerant From the viewpoint of global environmental protection make sure to us...

Page 15: ...or unit 2 Slightly pull out the auxiliary piping 3 Remove the 2 screws on the left side and unfasten the hook on the rear side 4 Unfasten the hook on the right side and lift up the indoor heat exchang...

Page 16: ...ies before disassembling work Step Procedure Points 1 Remove the screw of the right side plate 3 2 Unfasten the hook and remove the right side plate 3 Remove the fan rotor and the fan motor The fan mo...

Page 17: ...5 Pull out and remove the fan motor stator ASSY Unfasten the 2 hooks and disassemble the fan motor stator ASSY Step Procedure Points Hook Fan motor stator ASSY R24351 R24264 Fan motor cover body Beari...

Page 18: ...hooks at the bottom 1 2 Unfasten the 2 hooks at the bottom and remove the fan guard Remove the other fan guard in the same way 2 Remove the vertical blade ASSYs Each vertical blade ASSY has 5 fins It...

Page 19: ...Revision History Month Year Version Revised contents 01 2015 Si041417E First edition 12 2016 Si041417EA Model addition FTK09 12 18P5VL FTH09 12 18P5VL...

Page 20: ...ies supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acces...