background image

OPERATION MANUAL

MODELS

(Wall mounted type)

FAFC100AV1G

SPLIT SYSTEM         Air Conditioners

00_CV_3P642602-1E.indd   1

25-Feb-21   11:17:17 AM

Summary of Contents for FAFC100AV1G

Page 1: ...OPERATION MANUAL MODELS Wall mounted type FAFC100AV1G SPLIT SYSTEM Air Conditioners 00_CV_3P642602 1E indd 1 25 Feb 21 11 17 17 AM...

Page 2: ...00_CV_3P642602 1E indd 2 25 Feb 21 11 17 17 AM...

Page 3: ...irflow Rate 11 Adjusting the Airflow Direction 12 Useful Functions COMFORT AIRFLOW INTELLIGENT EYE Operation 13 POWERFUL Operation 15 ECONO OUTDOOR UNIT QUIET Operation 16 TIMER Operation ON OFF TIMER...

Page 4: ...air conditioner or otherwise fire may result Do not use a refrigerant other than the one indicated on the outdoor unit R32 when installing moving or repairing Using other refrigerants may cause troubl...

Page 5: ...or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be broken and the panel ma...

Page 6: ...normal operation and energy saving operation Page 13 14 Display OPERATION lamp green TIMER lamp orange Page 17 18 21 23 INTELLIGENT EYE lamp green Page 13 Signal receiver Receives signals from the re...

Page 7: ...the front panel Outdoor Unit Air filter Dust collection filter PM 2 5 White Air outlet Air inlet back and side Earth terminal inside Drain hose Refrigerant pipes and inter unit wire 01_EN_3P642602 1E...

Page 8: ...setting button Selects the airflow rate setting Page 11 POWERFUL button POWERFUL operation Page 15 ARC466A14 Display LCD Displays the current settings In this illustration each section is shown with...

Page 9: ...cels the timer setting Page 17 18 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET opera...

Page 10: ...iods of time The standard replacement time is 1 year Both batteries should be replaced at the same time Be sure to replace them with new size AAA LR03 alkaline batteries When battery power has run out...

Page 11: ...sent time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks NOTE Note on setting the clock If th...

Page 12: ...sappears from the LCD The OPERATION lamp goes off To change the temperature setting Press Press to raise the temperature and press to lower the temperature Each pressing of the button changes the temp...

Page 13: ...tumn turn off the circuit breaker The air conditioner always consumes a small amount of electricity even while it is not operating You can adjust the airflow rate to increase your comfort To adjust th...

Page 14: ...D airflow direction Press and and appear on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps or louvres will stop moving To set the flaps or louvres at...

Page 15: ...iolently push the INTELLIGENT EYE sensor This can lead to damage and malfunction To start Press and select the desired mode Each time is pressed a different setting option appears on the LCD When INTE...

Page 16: ...Note on COMFORT AIRFLOW operation The airflow rate will be set to AUTO If the up and down airflow direction is selected COMFORT AIRFLOW operation will be cancelled Notes on INTELLIGENT EYE operation A...

Page 17: ...increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL operation To maximise the cooling effect the capacity of out...

Page 18: ...operation is performed with lower power and therefore may not provide a sufficient cooling effect Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption lev...

Page 19: ...ting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappe...

Page 20: ...etting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the LCD The TIMER lamp goes off ON OFF TIMER co...

Page 21: ...ose for Monday Page 22 6 00 8 30 17 30 22 00 25 C 27 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 20 8...

Page 22: ...desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to selec...

Page 23: ...ctivated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 22 NOTE Notes on WEEKLY TIMER...

Page 24: ...will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be c...

Page 25: ...Proceed to Setting mode STEP 4 Page 20 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To deactivate WEEKLY TIMER...

Page 26: ...vations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press The day of the week and th...

Page 27: ...unds Rough materials such as a scrubbing brush Dust collection filter PM2 5 To purchase the filters Table 1 or to purchase the another type contact the dealer where you bought the air conditioner The...

Page 28: ...with water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with luke...

Page 29: ...filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from it Dust collection filter PM...

Page 30: ...ke out the batteries from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resultin...

Page 31: ...lowing sound This sound is generated when the flow of the refrigerant in the air conditioner is switched over Ticking sound This sound is generated when the cabinet and frame of the air conditioner sl...

Page 32: ...check the error code and consult your dealer Page 33 The air conditioner does not stop operating Case Description what to check The air conditioner continues operating even after operation is stopped...

Page 33: ...ry due to battery leakage rupturing or heating or lead to equipment failure Even when the LCD is blinking the OFF button remains functional Other electric devices start operating If the remote control...

Page 34: ...ly hot or damaged An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work...

Page 35: ...AULTY HEAT EXCHANGER TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MO...

Page 36: ...3P642602 1E M20N109B 2103 HT The two dimensional bar code is a manufacturing code Quick Reference 00_CV_3P642602 1E indd 3 25 Feb 21 11 17 18 AM...

Reviews: