Daikin EWAA011-016DAV3P Operation Manual Download Page 10

5 Operation

Operation manual

10

EWAA011~016DA + EWYA009~016DA

Packaged air-cooled water chillers

and packaged air to water heat pumps

4P620244-1B – 2021.02

5.4

Turning operation ON or OFF

5.4.1

Visual indication

Certain  functionalities  of  the  unit  can  be  enabled  or  disabled
separately.  If  a  functionality  is  disabled,  the  corresponding
temperature icon in the home screen will be greyed out.

Space heating/cooling operation

22

20

12

a

22

20

12

b

a

Space heating/cooling operation ON

b

Space heating/cooling operation OFF

5.4.2

To turn ON or OFF

Space heating/cooling operation

NOTICE

Room  frost  protection.

  Even  if  you  turn  OFF  space

heating/cooling  operation  ([C.2]: 

Operation

  > 

Space

heating/cooling

),  room  frost  protection  operation  –if

enabled–  can  still  activate.  However,  for  leaving  water
temperature  control  and  external  room  thermostat  control,
the protection is NOT guaranteed.

NOTICE

Water  pipe  freeze  prevention.

  Even  if  you  turn  OFF

space  heating/cooling  operation  ([C.2]: 

Operation

  >

Space heating/cooling

), water pipe freeze prevention –

if enabled– will remain active.

1

Go to [C.2]: 

Operation

 > 

Space heating/cooling

.

Operation

Space heating/cooling

On

C.2

2

Set operation to 

On

 or 

Off

.

5.5

Reading out information

To read out information

1

Go to [8]: 

Information

.

Possible read-out information

In menu…

You can read out…

[8.1] 

Energy data

Produced energy, consumed
electricity, and consumed gas

[8.2] 

Malfunction history

Malfunction history

[8.3] 

Dealer information

Contact/helpdesk number

[8.4] 

Sensors

Room temperature, outside
temperature, leaving water
temperature,…

[8.5] 

Actuators

Status/mode of each actuator

Example: 

Unit pump ON/OFF

In menu…

You can read out…

[8.6] 

Operation modes

Current operation mode

Example: 

Defrost/oil return

mode

[8.7] 

About

Version information about the
system

[8.8] 

Connection status

Information about the connection
status of the unit, the room
thermostat and WLAN.

[8.9] 

Running hours

Running hours of specific system
components

5.6

Space heating/cooling control

5.6.1

Setting the space operation mode

About space operation modes

Your unit can be a cooling or a heating/cooling model:

▪ If your unit is a cooling model, it can cool down a space.

▪ If your unit is a heating/cooling model, it can both heat up and cool

down a space. You have to tell the system which operation mode
to use.

To tell the system which space operation to use, you can:

You can…

Location

Check which space operation mode is
currently used.

Home screen

Set the space operation mode permanently. Main menu

Restrict automatic changeover according to
a monthly schedule.

To set the space operation mode

1

Go to [4.1]: 

Space heating/cooling

 > 

Operation

mode

2

Select one of the following options:

Heating

: Only heating mode

Cooling

: Only cooling mode

Automatic

The 

operation 

mode 

changes

automatically  between  heating  and  cooling  based
on the outdoor temperature. Restricted per month
according  to  the 

Operation  mode  schedule

[4.2].

To restrict automatic changeover according to a schedule

Conditions: 

You set the space operation mode to 

Automatic

.

1

Go to [4.2]: 

Space heating/cooling

 > 

Operation

mode schedule

.

2

Select a month.

3

For each month, select an option:

Reversible

: Not restricted

Heating only

: Restricted

Cooling only

: Restricted

4

Confirm the changes.

5.6.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

Summary of Contents for EWAA011-016DAV3P

Page 1: ...air to water heat pumps English Operation manual Packaged air cooled water chillers and packaged air to water heat pumps EWAA011 016DAV3P EWAA011 016DAW1P EWAA011 016DAV3P H EWAA011 016DAW1P H EWYA009...

Page 2: ...settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users...

Page 3: ...ans that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil...

Page 4: ...and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space INFORMATION H...

Page 5: ...ature b Desired room temperature To change the desired leaving water temperature You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature...

Page 6: ...used for SD cards USB connector With a USB memory stick the installer can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurato...

Page 7: ...Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule 1 9 Room comfort setpoint Heating comf...

Page 8: ...r unit f Main zone f1 Installed room thermostat type Unit operation is decided based on the ambient temperature of the dedicated Human Comfort Interface BRC1HHDA used as room thermostat Unit operation...

Page 9: ...ormation about the outdoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenan...

Page 10: ...le Unit pump ON OFF In menu You can read out 8 6 Operation modes Current operation mode Example Defrost oil return mode 8 7 About Version information about the system 8 8 Connection status Information...

Page 11: ...g water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2 Additional zone 3 2 Adjust the desired leaving water temperature 20 C 2 a b Main zone 12 C 3 a b Additional zone a Actual leavi...

Page 12: ...lear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In...

Page 13: ...mperature the unit relies on its weather dependent curve This curve defines how much the leaving water temperature must be at different outdoor temperatures Because the slope of the curve depends on l...

Page 14: ...ope offset When slope is selected set slope and go to offset When offset is selected set offset Confirm changes and return to the submenu 5 8 4 Using weather dependent curves Configure weather depende...

Page 15: ...have to Keep the area around the unit clean Keep the user interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure is above 1 bar Refrigerant This produc...

Page 16: ...to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not When Emergency is set to auto SH reduced DHW off or auto SH reduced DHW on 2 and a heat...

Page 17: ...by installer 10 1 Configuration wizard Setting Fill in System Backup heater type 9 3 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup heater Voltage 9 3 2 C...

Page 18: ......

Page 19: ......

Page 20: ...4P620244 1B 2021 02 Copyright 2020 Daikin 4P620244 1 B 0000000W Verantwortung f r Energie und Umwelt...