Daikin EWAA011-016DAV3P Operation Manual Download Page 9

5 Operation

Operation manual

9

EWAA011~016DA + EWYA009~016DA
Packaged air-cooled water chillers
and packaged air to water heat pumps
4P620244-1B – 2021.02

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.

See 

"8.1 To display the help text in

case of a malfunction"

 [

4

 15] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a

dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the outdoor
unit.

Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your
main zone emitter type.

Set the leaving water temperature for
the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.

Set the leaving water temperature for
the additional zone (if present).

[4]

 

Space heating/

cooling

Shows the applicable symbol of your
unit.

Put the unit in heating mode or cooling
mode. You cannot change the mode
on cooling only models.

[7]

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

[8]

 

Information

Displays data and information about
the outdoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality on or
off.

[D]

 

Wireless

gateway

Restriction: 

Only displayed if a

wireless LAN (WLAN) is installed.

Contains settings needed when
configuring the Daikin Residential
Controller app.

5.3.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Examples

[1] Room temperature screen

+

21

°C

1

Room

[2] Main zone screen

+

20

°C

2

Main zone

[3] Additional zone screen

+

12

°C

3

Additional zone

Explanation

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

5.3.4

Detailed screen with values

Example: 

a

b

c

a

b

c

7.2.1

Time/date

Hours

11

30

Minutes

a

Settings

b

Values

c

Selected setting and value

Possible actions on this screen

Go through the list of settings.

Change the value.

Go to the next setting.

Confirm changes and proceed.

Summary of Contents for EWAA011-016DAV3P

Page 1: ...air to water heat pumps English Operation manual Packaged air cooled water chillers and packaged air to water heat pumps EWAA011 016DAV3P EWAA011 016DAW1P EWAA011 016DAV3P H EWAA011 016DAW1P H EWYA009...

Page 2: ...settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users...

Page 3: ...ans that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil...

Page 4: ...and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space INFORMATION H...

Page 5: ...ature b Desired room temperature To change the desired leaving water temperature You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature...

Page 6: ...used for SD cards USB connector With a USB memory stick the installer can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurato...

Page 7: ...Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule 1 9 Room comfort setpoint Heating comf...

Page 8: ...r unit f Main zone f1 Installed room thermostat type Unit operation is decided based on the ambient temperature of the dedicated Human Comfort Interface BRC1HHDA used as room thermostat Unit operation...

Page 9: ...ormation about the outdoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenan...

Page 10: ...le Unit pump ON OFF In menu You can read out 8 6 Operation modes Current operation mode Example Defrost oil return mode 8 7 About Version information about the system 8 8 Connection status Information...

Page 11: ...g water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2 Additional zone 3 2 Adjust the desired leaving water temperature 20 C 2 a b Main zone 12 C 3 a b Additional zone a Actual leavi...

Page 12: ...lear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In...

Page 13: ...mperature the unit relies on its weather dependent curve This curve defines how much the leaving water temperature must be at different outdoor temperatures Because the slope of the curve depends on l...

Page 14: ...ope offset When slope is selected set slope and go to offset When offset is selected set offset Confirm changes and return to the submenu 5 8 4 Using weather dependent curves Configure weather depende...

Page 15: ...have to Keep the area around the unit clean Keep the user interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure is above 1 bar Refrigerant This produc...

Page 16: ...to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not When Emergency is set to auto SH reduced DHW off or auto SH reduced DHW on 2 and a heat...

Page 17: ...by installer 10 1 Configuration wizard Setting Fill in System Backup heater type 9 3 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup heater Voltage 9 3 2 C...

Page 18: ......

Page 19: ......

Page 20: ...4P620244 1B 2021 02 Copyright 2020 Daikin 4P620244 1 B 0000000W Verantwortung f r Energie und Umwelt...

Reviews: