9
|
Electrical installation
Installer reference guide
117
EPRA14~W1 + ETSH/X(B)16P30+50EF
Daikin Altherma 3 H HT ECH₂O
4P679467-1 – 2022.02
Item
Description
Human Comfort Interface
See:
▪
Installation and operation manual of the
Human Comfort Interface
▪
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9]
Control
[1.6]
Room sensor offset
WLAN module
See:
▪
Installation manual of the WLAN module
▪
Addendum book for optional equipment
Use the cable delivered with the WLAN
module.
[D]
Wireless gateway
for room thermostat (wired or wireless):
In case of…
See…
Wireless room thermostat
▪
Installation manual of the wireless room
thermostat
▪
Addendum book for optional equipment
Wired room thermostat
without multi-zoning base unit
▪
Installation manual of the wired room
thermostat
▪
Addendum book for optional equipment
Wired room thermostat with
multi-zoning base unit
▪
Installation manual of the wired room
thermostat (digital or analogue) + multi-zoning
base unit
▪
Addendum book for optional equipment
▪
In this case:
-
You need to connect the wired room
thermostat (digital or analogue) to the
multi-zoning base unit
-
You need to connect the multi-zoning base
unit to the outdoor unit
-
For cooling/heating operation, you also
need to implement a relay (field supply, see
addendum book for optional equipment)
9.3.1 To connect the electrical wiring to the indoor unit
Remark
: All cables which will be connected to the switch box of the ECH
2
O must be
fixed by strain relief.
To have easier access to the switch box itself and the routing of cables the switch
box can be lowered (see