9
|
Configuration
Installer reference guide
108
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
#
Code
Description
N/A
[D‑08]
Optional external kWh meter 1:
▪
0 (
No
): NOT installed
▪
1: Installed (0.1
pulse/kWh
)
▪
2: Installed (1
pulse/kWh
)
▪
3: Installed (10
pulse/kWh
)
▪
4: Installed (100
pulse/kWh
)
▪
5: Installed (1000
pulse/kWh
)
N/A
[D‑09]
Optional external kWh meter 2:
▪
0 (
No
): NOT installed
▪
1: Installed (0.1
pulse/kWh
)
▪
2: Installed (1
pulse/kWh
)
▪
3: Installed (10
pulse/kWh
)
▪
4: Installed (100
pulse/kWh
)
▪
5: Installed (1000
pulse/kWh
)
9.2.4 Space heating/cooling control
Leaving water temperature: Main zone
#
Code
Description
[A.3.1.1.1]
N/A
Select the setpoint mode of the leaving water
temperature.
LWT setpoint mode
:
▪
0 (
Fixed
): Absolute
▪
1 (
Weather dep.
): Weather-dependent
▪
2
(
Fixed/scheduled
):
Absolute
+
scheduled (only if
Unit
control
method
=
LWT control
)
▪
3 (
WD/scheduled
): Weather-dependent +
scheduled (only if
Unit
control
method
=
LWT control
)
[7.7.1.1]
[1-00]
[1-01]
[1-02]
[1-03]
If you selected weather-dependent curve as a
setpoint mode, adjust the curve to your needs.
(a)
Set weather-dependent heating
:
[1-03]
[1-02]
Ta
Tt
[1-00]
[1-01]
▪
T
t
: Target leaving water temperature (main)
▪
T
a
: Outdoor temperature
(a)
Also see
112].
Summary of Contents for ERLA03DAV3
Page 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Page 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...