16
|
Technical data
Installer reference guide
262
EPRA08~W1 + ETVH/9W
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03
16.2 Piping diagram: Outdoor unit
3D127127
R10T
R9T
R
6T
R
3T
R5T
R
4T
R
1T
R2T
S1PH
sv
sv
M1C
S1NPH
E1HHEX
sv
S2
PH
Y1E
Y3E
Y2S
M1F
Y4S
Y3S
Liquid
Gas
Y1S
R7T
Q1E
b
d
e
n
n
c
d
i
j
k
l
g
i
i
i
f
f
f
f
m
h
a
e
o
Gas
Gas
Thermistors:
Liquid
Liquid
R1T
Thermistor - outdoor air
a
Water IN (screw connection, male, 1")
R2T
Thermistor - compressor discharge
b
Water OUT (screw connection, male, 1")
R3T
Thermistor - compressor suction
c
Plate heat exchanger
R4T
Thermistor - air heat exchanger, distributor
d
Pinched pipe
R5T
Thermistor - air heat exchanger, middle
e
Refrigerant filter
R6T
Thermistor - refrigerant liquid
f
One-way valve
R7T
Thermistor - injection
g
Economiser heat exchanger
R9T
Thermistor - entering water
h
Service port 5/16" flare
R10T
Thermistor - leaving water
i
Capillary tube
j
Distributor
k
Air heat exchanger
Refrigerant flow:
l
PCB cooling
Heating
m
Accumulator
Cooling
n
Muffler
o
Casing
E1HHEX
Plate heat exchanger heater
M1C
Compressor
M1F
Fan motor
S1PH
High pressure switch (4.6 MPa)
S2PH
High pressure switch (4.17 MPa)
S1NPH
High pressure sensor
Y1E
Electronic expansion valve (main)
Y3E
Electronic expansion valve (injection)
Y1S
Solenoid valve (4-way valve)
Y2S
Solenoid valve (low pressure bypass)
Y3S
Solenoid valve (hot gas bypass)
Y4S
Solenoid valve (liquid injection)
Q1E
Overload
Summary of Contents for EPRA08EAV3
Page 289: ...13 13...
Page 290: ......
Page 291: ......
Page 292: ...4P634886 1 2021 03 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...