background image

1

EKWCTRAN1V3

The EKWCTRAN1V3 is intended for regulating the room temperature by 

setting the desired target temperature for the activation of actuators in 

heating/cooling operation. Every other use is considered not intended; 

the manufacturer cannot be held liable for unintented use.

1x

2x

Installation position

External heat 

sources will impact 

the thermostat’s 

performance.

2 K

1

2

 

¾

The electrical installation must be performed according to the 

current national VDE regulations as well as according to the 

regulations of your local electric power utility company, by an 

authorised and trained electrician, and in a de-energized state.

 

¾

Only an authorised electrician may open the device. It may only 

be opened in de-energized state.

 

¾

Only use the device if it is in perfect state.

 

¾

Ensure that children do not play with this device. Children must 

be monitored if necessary.

Installation

Mount the thermostat directly on the wall or on a flush-type box. Make the 

electric connection as shown in figure 3.

The thermostat can be 

used in heating and cooling 

systems. If you want to block 

the cooling function, connect 

the lower left contacts to 

each other in de-energized 

state.

*

 Protective cover

Setback temperature

The reduction of 2 K can be activated to   by  

L/L1, e. g. by an external timer.

CO

µC

2b

1

4

2a

3,5 mm

3

60 mm

*

ANALOGUE THERMOSTAT 230 V

Dismantling

1. 

Switch off the voltage supply.

2.  Remove the wiring.

3. 

Take off the thermostat and dispose of it properly.

2x

20

15

10

25

28

-2K

-1

+1 +2K

0

3

2

2

4

1

1

Target value regulator

Set the target temperature by rotating the target value 

regulator

Target value calibration

1.  Remove the target value 

regulator.

2.  Set the target value 

correction: An alignment 

to the room temperature 

is possible between  

-2 K ... +2 K.

Optional – Limiting the 

temperature range

Insert and set the limiters 

for minimum and maximum 

temperature.

https://qr.daikin.eu?N=EKWCTRAN1V3