3 About the system

Operation manual

4

EKHWET90~120BAV3

R32 Split series – Domestic hot water tank

4P680075-1B – 2022.02

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

▪ The refrigerant inside the unit is

mildly flammable, but normally does
NOT leak. If the refrigerant leaks in
the room and comes in contact with
fire from a burner, a heater, or a
cooker, this may result in fire, or the
formation of a harmful gas.

▪ Turn OFF any combustible heating

devices, ventilate the room, and
contact the dealer where you
purchased the unit.

▪ Do NOT use the unit until a service

person confirms that the part from
which the refrigerant leaked has been
repaired.

3

About the system

Depending on the system layout, the system can:

▪ Produce domestic hot water

3.1

Components in a typical system
layout

d

b

a

c

C

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface of the indoor unit

4

Quick guide

4.1

User permission level

The  amount  of  information  you  can  read  and  edit  in  the  menu
structure depends on your user permission level:

User

: Standard mode

Advanced user

: You can read and edit more information

To change the user permission level

1

Go to [B]: 

User profile

.

User profile

B

2

Enter the applicable pin code for the user permission
level.

▪ Browse  through  the  list  of  digits  and  change  the

selected digit.

▪ Move the cursor from left to right.

▪ Confirm the pin code and proceed.

User pin code

The 

User

 pin code is 

0000

.

0000

User

Advanced user pin code

The 

Advanced user

 pin code is 

1234

. Additional menu items for the

user are now visible.

1234

Advanced user

4.2

Domestic hot water

To turn tank heating operation ON or OFF

NOTICE

Disinfection  mode

.  Even  if  you  turn  OFF  tank  heating

operation ([C.3]: 

Operation

 > 

Tank

), disinfection mode will

remain  active.  However,  if  you  turn  it  OFF  while
disinfection is running, an AH error occurs.

1

Go to [C.3]: 

Operation

 > 

Tank

.

Operation

Tank

Off

C.3

2

Set operation to 

On

 or 

Off

.

To change the tank temperature setpoint

In 

Reheat  only

  mode,  you  can  use  the  tank  temperature  setpoint

screen to read out and adjust the domestic hot water temperature.

Summary of Contents for EKHWET90BAV3

Page 1: ...Operation manual R32 Split series Domestic hot water tank English Operation manual R32 Split series Domestic hot water tank EKHWET90BAV3 EKHWET120BAV3...

Page 2: ...ure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If NOT request hi...

Page 3: ...onic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and of other parts MUST be do...

Page 4: ...User interface of the indoor unit 4 Quick guide 4 1 User permission level The amount of information you can read and edit in the menu structure depends on your user permission level User Standard mod...

Page 5: ...ser interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the screens menus and settings of the...

Page 6: ...7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule Level 5 Tank Powerful operation Comfort setpoint Eco setpoint Reheat setpoint Schedule WD curve WD curve type D Wireless gateway Mode Re...

Page 7: ...uiet mode active e3 Outdoor unit f Indoor unit domestic hot water tank f Wall mounted indoor unit with integrated tank g Holiday mode Holiday mode active h Malfunction A malfunction occurred See 8 1 T...

Page 8: ...alues c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Possible actions on this screen Confirm changes and proceed 5...

Page 9: ...vailable again During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again At 00 00 the next day the cycle repeats 5 6 3 Scheduled reheat mode In schedule...

Page 10: ...1 Select the day of which you want to clear the content For example Friday Mon Sat Wed Fri Thu Tue Sun User defined C 2 Select Delete Delete Edit Copy 3 Select OK to confirm To program the schedule f...

Page 11: ...on its weather dependent curve This curve defines how much the target temperature of the tank must be at different outdoor temperatures Because the slope of the curve depends on local circumstances s...

Page 12: ...t Confirm changes and return to the submenu 5 8 4 Using weather dependent curves Configure weather dependent curves as following To define the setpoint mode To use the weather dependent curve you need...

Page 13: ...oster heater is allowed either after a certain amount of time has passed since start of DHW operation refer below or when outdoor unit is unable to perform DHW Quick mode timer When Quick mode is chos...

Page 14: ...taller 8 2 To check the malfunction history Conditions The user permission level is set to advanced end user 1 Go to 8 2 Information Malfunction history You see a list of the most recent malfunctions...

Page 15: ...e malfunction a We recommend to purge air with the air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air...

Page 16: ...4P680075 1B 2022 02 Copyright 2021 Daikin 4P680075 1 B 0000000 Verantwortung f r Energie und Umwelt...

Reviews: