9
|
Electrical installation
Installer reference guide
47
E120B
R32 Split series – Domestic hot water tank
4P680077-1A – 2022.11
Use the following methods for installing wires:
Wire type
Installation method
Single-core wire
Or
Stranded conductor wire
twisted to "solid-like"
connection
c b
c
a
a
A
AA´
A´
a
Curled wire (single-core or twisted stranded
conductor wire)
b
Screw
c
Flat washer
Stranded conductor wire
with round crimp-style
terminal
c b
b
a
c
a
B
B
a
Terminal
b
Screw
c
Flat washer
Allowed
NOT allowed
Tightening torques
Indoor unit:
Item
Tightening torque (N•m)
X2M
2.45 ±10%
X5M
0.88 ±10%
X8M
2.45 ±10%
M4 (earth)
1.47 ±10%
9.1.3 About electrical compliance
Only for the booster heater of the indoor unit
See
"9.2.2 To connect the booster heater power supply"