background image

EKHVWQ0 E260AA1V3

Domestic hot water heat pump

4PW65343-1A – 10.2010

Operation manual

2

1. D

EFINITIONS

1.1.

Meaning of warnings and symbols

Warnings in this manual are classified according to their severity and
probability of occurrence.

Some types of danger are represented by special symbols:

1.2.

Meaning of used terms

Installation manual:

Instruction manual specified for a certain product or application,
explaining how to install, configure and maintain it.

Operation manual:

Instruction manual specified for a certain product or application,
explaining how to operate it.

Maintenance instructions:

Instruction manual specified for a certain product or application,
which explains (if relevant) how to install, configure, operate and/or
maintain the product or application.

Dealer:

Sales distributor for products as per the subject of this manual.

Installer:

Technical skilled person who is qualified to install products as per the
subject of this manual.

User:

Person who is owner of the product and/or operates the product.

Service company:

Qualified company which can perform or coordinate the required
service to the unit.

Applicable legislation:

All international, European, national and local directives, laws,
regulations and/or codes which are relevant and applicable for a
certain product or domain.

Accessories:

Equipment which is delivered with the unit and which needs to be
installed according to instructions in the documentation.

Optional equipment: 

Equipment which can optionally be combined to the products as per
the subject of this manual.

Field supply:

Equipment which needs to be installed according to instructions in
this manual, but which are not supplied by Daikin.

2.

G

ENERAL

 S

AFETY

 

PRECAUTIONS

The precautions listed here are divided into the following four types.
They all cover very important topics, so be sure to follow them
carefully.

DANGER

Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.

WARNING

Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.

NOTICE

Indicates situations that may result in equipment or
property-damage accidents only.

INFORMATION

This symbol identifies useful tips or additional information.

Electric current.

Danger of burning and scalding.

DANGER: ELECTRICAL SHOCK

Switch off all power supply before removing the switchbox
service panel or before making any connections or
touching electrical parts.

Do not touch any switch with wet fingers. Touching a switch
with wet fingers can cause electrical shock. Before
touching electrical parts, turn off all applicable power
supply.

To avoid electric shock, be sure to disconnect the power
supply 1 minute or more before servicing the electrical
parts. Even after 1 minute, always measure the voltage at
the terminals of main circuit capacitors or electrical parts
and, before touching, be sure that those voltages are
50 V DC or less.

When service panels are removed, live parts can easily be
touched by accident. Never leave the unit unattended
during installation or servicing when the service panel is
removed.

DANGER: DO NOT TOUCH PIPING AND INTERNAL
PARTS

Do not touch the refrigerant piping, water piping or internal
parts during and immediately after operation. The piping
and internal parts may be hot or cold depending on the
working condition of the unit.

Your hand may suffer burns or frostbite if you touch the
piping or internal parts. To avoid injury, give the piping and
internal parts time to return to normal temperature or, if
you must touch them, be sure to wear protective gloves.

WARNING

Never directly touch any accidental leaking
refrigerant. This could result in severe wounds caused
by frostbite.

Do not touch the refrigerant pipes during and
immediately after operation as the refrigerant pipes
may be hot or cold, depending on the condition of the
refrigerant flowing through the refrigerant piping,
compressor, and other refrigerant cycle parts.

Your hands may suffer burns or frostbite if you touch
the refrigerant pipes. To avoid injury, give the pipes
time to return to normal temperature or, if you must
touch them, be sure to wear proper gloves.

CAUTION

Do not rinse the unit. This may cause electric shocks or
fire.

Summary of Contents for EKHVWQ002AAV3

Page 1: ...OPERATION MANUAL EKHVWQ002AAV3 EKHHS200AA1V3 EKHHS260AA1V3 Domestic hot water heat pump...

Page 2: ...nce activities 16 7 3 Standstill 16 8 Troubleshooting 17 9 Disposal requirements 17 The English text is the original instruction Other languages are translations of the original instructions This appl...

Page 3: ...es a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTICE Indicates situations that may result in eq...

Page 4: ...al 4 1 Domestic water heating operation quick start up Schedule timer operation Continuous operation Powerful operation INFORMATION Refer to the installation manual of the unit for installation proced...

Page 5: ...ers full control over your installation Basic controller functions The basic controller functions are Turning the unit ON OFF Schedule timer continuous mode Selection of features quiet mode refer to p...

Page 6: ...available 14 DEFROST MODE ICON d This icon indicates that the defrost mode is active 15 COMPRESSOR ICON This icon indicates that the compressor of the heat pump unit is active When freeze protection m...

Page 7: ...by 10 minutes 3 Use the wi or wj button to adjust the day of the week Each time the wi or wj button is pressed the next or previous day is displayed 4 Press the button to con rm the current set time...

Page 8: ...command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 12 INFORMATION Default the schedule timer is set as follows Time Set po...

Page 9: ...The desired quiet mode is set through a eld setting Refer to the eld settings explained in the installation manual for a detailed description how to set one or more eld settings Disinfection operation...

Page 10: ...ore actions are programmed for the same day and at the same time only the action with the lowest action number will be executed You can always alter add or remove the programmed actions later Example...

Page 11: ...e g 4 and 5 are not displayed 7 Press the button for 5 seconds to enter the programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the pi and pj bu...

Page 12: ...ogramming mode 6 Use the button to select the action number you would like to program or to modify 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect...

Page 13: ...e after pressing the button for 5 seconds press the pr button once You can now select another day by using the pi and pj buttons and restart consulting and programming Copying programmed actions to ne...

Page 14: ...P button is pressed the heat pump module heats up the domestic hot water tank as fast as possible to a prede ned setpoint This means that the inverter compressor frequency will be higher then in norm...

Page 15: ...bled de nes whether the reheat operation is turned ON 1 or OFF 0 1 Automatic domestic hot water tank temperature set point calculation 1 00 Renewal time for set point calculation The automatic tempera...

Page 16: ...ated setting 1 ON 02 Installation related setting 23 00 03 Installation related setting 0 OFF 04 Installation related setting 32 3 Miscellaneous 00 Installation related setting 1 ON 01 Installation re...

Page 17: ...issipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there...

Page 18: ...ed treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health...

Page 19: ......

Page 20: ...4PW65343 1A 10 2010 Copyright 2010 Daikin...