background image

EKHVWQ0 E260AA1V3

Domestic hot water heat pump

4PW65343-1A – 10.2010

Operation manual

16

7.

M

AINTENANCE

7.1.

Important information regarding the refrigerant 
used

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.

Refrigerant type:

R410A

GWP

(1)

 value:

1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.

7.2.

Maintenance activities

In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals, preferably yearly.

The only maintenance which may be required by the operator is:

keeping the remote controller clean by means of a soft damp
cloth,

A check for correct operation of the field installed pressure relief
valve installed on your domestic hot water tank, has to be
carried out at least every 6 months: it is important that the lever
on the valve is actuated to prevent accumulation of mineral
deposits that may impair valve operation and to confirm that the
valve and discharge pipe are not blocked. The lever should be
operated slowly and smoothly to avoid a sudden rush of hot
water from the discharge pipe.
Failure to operate the relief valve actuating lever may result in
the water heater exploding.

Continuous leakage of water from the discharge pipe may
indicate a problem with the water heater.

If a discharge pipe is connected to the pressure relief device it
must be installed in a continuously downward direction and in a
frost-free environment. It must be left open to the atmosphere.

7.3.

Standstill

If the domestic hot water is not used for two weeks or more, a
quantity of hydrogen gas which is highly flammable may
accumulate in the domestic hot water tank. To dissipate this gas
safely, it is recommended that a hot tap be turned on for several
minutes at a sink, basin, or bath, but not at a dishwasher, clothes
washer or other appliance. During this procedure there must be
no smoking, open flame or any electrical appliance operating
nearby. If hydrogen is discharged through the tap, it will probably
make a sound as of air escaping.

Each inspection has to be carried out by your local
Daikin technician and 

not by the user

.

Do not touch water pipes immediately after operation
as the pipes may be hot. Your hand may suffer burns.
To avoid injury, give the piping time to return to normal
temperature or be sure to wear proper gloves.

WARNING

Before carrying out any maintenance or repair activity,
always switch off the circuit breaker on the supply
panel, remove the fuses or open the protection
devices of the unit.

Do not touch live parts for 10 minutes after the power
supply is turned off because of high voltage risk.

Do not touch any switch with wet fingers. Touching a
switch with wet fingers can cause electrical shock.

Please note that some sections of the electric
component box are hot.

Make sure you do not touch a conductive section.

Do not rinse the unit. This may cause electric shocks
or fire.

Play it safe!

Touch a metal part by hand (such as the stop valve) in
order to eliminate static electricity and to protect the PCB
before performing service.

WARNING

Do not touch water pipes during and immediately after
operation as the pipes may be hot.

Do not touch the refrigerant pipes during and
immediately after operation as the refrigerant pipes
may be hot or cold, depending on the condition of the
refrigerant flowing through the refrigerant piping,
compressor, and other refrigerant cycle parts.

Your hands may suffer burns or frostbite if you touch the
pipes. To avoid injury, give the pipes time to return to
normal temperature or, if you must touch them, be sure to
wear proper gloves.

WARNING

Switching off the power supply stops the automatic
repetitive movement of the pump in order to prevent it from
getting jammed.

Summary of Contents for EKHVWQ002AAV3

Page 1: ...OPERATION MANUAL EKHVWQ002AAV3 EKHHS200AA1V3 EKHHS260AA1V3 Domestic hot water heat pump...

Page 2: ...nce activities 16 7 3 Standstill 16 8 Troubleshooting 17 9 Disposal requirements 17 The English text is the original instruction Other languages are translations of the original instructions This appl...

Page 3: ...es a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTICE Indicates situations that may result in eq...

Page 4: ...al 4 1 Domestic water heating operation quick start up Schedule timer operation Continuous operation Powerful operation INFORMATION Refer to the installation manual of the unit for installation proced...

Page 5: ...ers full control over your installation Basic controller functions The basic controller functions are Turning the unit ON OFF Schedule timer continuous mode Selection of features quiet mode refer to p...

Page 6: ...available 14 DEFROST MODE ICON d This icon indicates that the defrost mode is active 15 COMPRESSOR ICON This icon indicates that the compressor of the heat pump unit is active When freeze protection m...

Page 7: ...by 10 minutes 3 Use the wi or wj button to adjust the day of the week Each time the wi or wj button is pressed the next or previous day is displayed 4 Press the button to con rm the current set time...

Page 8: ...command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 12 INFORMATION Default the schedule timer is set as follows Time Set po...

Page 9: ...The desired quiet mode is set through a eld setting Refer to the eld settings explained in the installation manual for a detailed description how to set one or more eld settings Disinfection operation...

Page 10: ...ore actions are programmed for the same day and at the same time only the action with the lowest action number will be executed You can always alter add or remove the programmed actions later Example...

Page 11: ...e g 4 and 5 are not displayed 7 Press the button for 5 seconds to enter the programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the pi and pj bu...

Page 12: ...ogramming mode 6 Use the button to select the action number you would like to program or to modify 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect...

Page 13: ...e after pressing the button for 5 seconds press the pr button once You can now select another day by using the pi and pj buttons and restart consulting and programming Copying programmed actions to ne...

Page 14: ...P button is pressed the heat pump module heats up the domestic hot water tank as fast as possible to a prede ned setpoint This means that the inverter compressor frequency will be higher then in norm...

Page 15: ...bled de nes whether the reheat operation is turned ON 1 or OFF 0 1 Automatic domestic hot water tank temperature set point calculation 1 00 Renewal time for set point calculation The automatic tempera...

Page 16: ...ated setting 1 ON 02 Installation related setting 23 00 03 Installation related setting 0 OFF 04 Installation related setting 32 3 Miscellaneous 00 Installation related setting 1 ON 01 Installation re...

Page 17: ...issipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there...

Page 18: ...ed treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health...

Page 19: ......

Page 20: ...4PW65343 1A 10 2010 Copyright 2010 Daikin...

Reviews: