Daikin EKHTSU200AA Installation Manual Download Page 5

 

EK260AA + EKUHWHTA

 

Domestic hot water tank with UK kit for air to water heat pump system

 

4PW53247-1B

 

Installation manual

 

3

 

Safety devices

 

 

Thermal protector — The EKHBRD indoor unit is equipped with
a thermal protector. The thermal protector is activated when the
temperature becomes too high. When activated, the protector
has to be reset on the indoor unit by pressing the red button (for
access, remove the decoration panels like indicated in the
manual of the indoor unit). 

 

 

Temperature and pressure relief valve

The temperature and pressure relief valve prevents excessive
water temperature (>95°C) and excessive water pressure
(

 

 

10 bar) in the domestic hot water tank.

 

 

Expansion relief valve (EKUHWHTA kit)

The pressure relief valve prevents excessive water pressure
(

 

 

8 bar) in the water circuit.

 

Outlook diagram

 

 

The domestic hot water tank relief valve connections
may not be used for other purpose.

 

 

This domestic hot water tank can only be used with an
EKHBRD indoor unit.

 

Switch off the power supply before opening the
decoration panels of the indoor unit.

 

NOTE

 

Refer to 

"Installation of the EKUHWHTA kit on the

domestic hot water tank" on page 8

  for connection of

other safety devices in accordance with relevant local
and national regulations.

11

10

12

12

13

2

1

5

4

6

8

3

9

1

2

7

772

902

1032

H1

120

Ø60

H2

778

694

443

600

300

11

5

3

9

4

10

B

C

>250

>250

30

D

>30

A

>600

 

1

 

Hot water out connection (G 3/4" Female)

 

2

 

Cold water in connection (G 3/4" Female)

 

3

 

Hot water out connection at the bottom of the tank (quick coupling)

 

4

 

Cold water in connection at the bottom of the tank (quick coupling)

 

5

 

Recirculation connection (G 1/2" Male)

 

6

 

Flow inlet connection from the main EKHBRD indoor unit (quick coupling)

 

7

 

Return outlet connection to the main EKHBRD indoor unit (quick coupling)

 

8

 

3-way valve

 

9

 

Flow inlet connection from the main EKHBRD indoor unit at the bottom of the tank (quick coupling)

 

10

 

Return outlet connection to the main EKHBRD indoor unit at the bottom of the tank (quick coupling)

 

11

 

Temperature and pressure relief valve (15 mm Male)

 

12

 

Knockout holes for water piping

 

13

 

Levelling feet (on EKHBRD unit)

 

Domestic hot water tank model

H1

H2

EKHTSU200AA

 

2010 mm

1847 mm

 

EKHTSU260AA

 

2285 mm

2122 mm

Summary of Contents for EKHTSU200AA

Page 1: ...INSTALLATION MANUAL EKHTSU200AA EKHTSU260AA EKUHWHTA Domestic hot water tank with UK kit for air to water heat pump system...

Page 2: ...5x 1x 1x 1x 1 3 6 7 5 2 4 1x 340 mm 11 10 12 12 13 2 1 5 4 6 8 3 9 1 2 7 772 902 1032 H 120 6 0 1156 778 653 694 443 600 300 5 B C 250 250 A 600 30 D 30 2x 8 9 6 1 2 1 2 5 9 3 5 9 3 7 6 10 10 4 10 4...

Page 3: ...ct to building regulation approval notify Local Authority of intention to install The EKHTSU domestic hot water tank can only be connected to a EKHBRD indoor unit The domestic hot water tank is availa...

Page 4: ...oupler 22 mm 15 mm 5 Expansion vessel of 18 litres 6 Tundish 7 Elbow Drain valve 22 mm x 3 4 Male BSP 8 Adaptor 22 mm x 3 4 Female BSP 9 T piece 22 mm x 22 mm x 22 mm 10 Instruction sheet 1x 1x 1x 1x...

Page 5: ...before opening the decoration panels of the indoor unit NOTE Refer to Installation of the EKUHWHTA kit on the domestic hot water tank on page 8 for connection of other safety devices in accordance wi...

Page 6: ...itch the panel Mount the top plate of the indoor unit on the domestic hot water tank module 4 Connect the 3 way valve 1 Remove drain plate on top of the indoor unit before installing the 3 way valve 2...

Page 7: ...ifted slightly manual operation is possible 8 Make sure to firmly fix the power supply cord onto the 3 way valve body with a field supplied cable tie like in illustration below 9 Perform the wiring in...

Page 8: ...t water tank on page 8 10 Connect the thermistor wire to the indoor unit switch box Make sure power supply is switched off Refer to the wiring diagram delivered with the indoor unit The distance betwe...

Page 9: ...re and pressure relief valve to ensure free water flow through the discharge pipe turn knob left Refer to Main components on page 2 for location of the temperature and pressure relief valve 13 Reattac...

Page 10: ...pipework All pipework must have a continuous fall Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes All pipework and fittings must be flushed free of all flux and de...

Page 11: ...ne strainer and the expansion relief valve parts 1 and 2 of this kit see also procedure step 2 as high as possible and connect it to the water mains inlet The expansion relief valve must be installed...

Page 12: ...sing and correcting certain troubles which may occur in the unit General guidelines Before starting the trouble shooting procedure carry out a thorough visual inspection of the unit and look for obvio...

Page 13: ...then contact your local dealer EKHTSU200AA EKHTSU260AA Storage capacity l 200 260 Material Stainless steel Stainless steel Overall dimensions h x l x w mm 1335 x 600 x 695 1610 x 600 x 695 Operating...

Page 14: ...4PW53247 1B Copyright Daikin...

Reviews: