11
|
Configuration
Installer reference guide
178
EBLA04~E23V3 + EDLA04~E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05
This function defines how much the water temperature may drop below the
desired leaving water temperature before the compressor stops. The compressor
will start up again when the leaving water temperature rises above the desired
leaving water temperature.
#
Code
Description
N/A
[9-09]
Undershoot:
▪
1°C~18°C
Antifrost
Antifrost
[1.4] or [4.C] prevents the room from getting too cold. For more
information about room frost protection, see
150].
11.6.6 Tank
Overview
The following items are listed in the submenu:
5
Tank
User settings
Space heating/cooling
Additional zone
Information
[5]
Tank
Setpoint screen
[5.1]
Powerful operation
[5.2]
Comfort setpoint
[5.3]
Eco setpoint
[5.4]
Reheat setpoint
[5.5]
Schedule
[5.6]
Heat up mode
[5.7]
Disinfection
[5.8]
Maximum
[5.9]
Hysteresis
[5.A]
Hysteresis
[5.B]
Setpoint mode
[5.C]
WD curve
[5.D]
Margin
[5.E]
WD curve type
Tank setpoint screen
You can set the domestic hot water temperature using the setpoint screen. For
more information about how to do this, see
Powerful operation
You can use powerful operation to immediately start heating up the water to the
preset value (Storage comfort). However, this consumes extra energy. If powerful
operation is active,
will be shown on the home screen.
To activate powerful operation
Activate or deactivate
Powerful operation
as follows:
1
Go to [5.1]:
Tank
>
Powerful operation
2
Turn powerful operation
Off
or
On
.