7
|
Technical data
Service manual
297
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
7.3 Piping diagram
7.3.1 Piping diagram: Outdoor unit
EBLA04~08E23V3, EDLA04~08E23V3
A
B
a2
j
i
h
g
f
b
B
1P
R
m
l
u
n
o
p
q
S1
PH
t
s
r
t
k
e
a1
c
d
b
B1
PW
3D139436 A
R2T
R1T
R2T
R3T
R1T
R4T
R3T
A Hydro module
B1PW
Space heating water pressure sensor
B Compressor module
B1PR
Refrigerant pressure sensor
S1PH
High pressure switch
A1
Water IN (screw connection, male, 1")
A2
Water OUT (screw connection, male, 1")
Thermistors (hydro module):
b
Drain valve (water circuit)
R1T
Outlet water heat exchanger
c
Expansion vessel
R3T
Refrigerant liquid side
d
Flow sensor
R4T
Inlet water
e
Plate heat exchanger
f
Backup heater
Thermistors (compressor module):
g
Automatic air purge valve
R1T
Outdoor air
h
Safety valve
R2T
Air heat exchanger
i
Pump
R3T
Compressor discharge
j
Connection for optional flow switch
k
Liquid stop valve
Refrigerant flow:
l
Filter
Heating
m
Electronic expansion valve
Cooling
n
Muffler with filter
o
Distributor
Connections:
p
Heat exchanger
Screw connection
q
4‑way valve
Flare connection
r
Accumulator
Quick coupling
s
Compressor
Brazed connection
t
Muffler
u
Gas stop valve with service port
draft – 31/05/2022 15:53