4 Installation
Installation manual
24
D2CND024A1/4AB + D2TND012~024A4AB
Wall-mounted condensing boiler
3P469346-3N – 2019.11
Allowable flue length for B53
Flue duct 60 mm
24.0 m
20.0 m
Flue duct 80 mm
130.0 m
112.0 m
Equivalent length of options
90° elbow 60 mm
1.5 m
45° elbow 60 mm
1.0 m
90° elbow 80 mm
2.0 m
45° elbow 80 mm
1.0 m
Subtract equivalent length value of bends from the allowable flue
length value.
a
c
d
e
L
b
a
90° elbow 60 mm
b
Extension 60 mm
Optional:
c
90° elbow 60 mm
d
45° elbow 60 mm
e
Extension 60 mm
L= 250-500-1000-1500-2000 mm
Flue parts order codes
Required flue kits and/or additional parts can be ordered from Daikin
with the order codes given in the table below:
Flue part
Order code
Wall terminal kit 60/100 (C13x)
DRWTER60100AA
Wall terminal kit 80/125 (C13x)
EKFGW6359
Roof terminal kit 60/100 (C33x)
EKFGP6837
Roof terminal kit 80/125 (C33x)
EKFGP6864
Tee 60/100 with measurement point
EKFGP4667
90° elbow 60/100 (boiler outlet)
DRMEEA60100BA
90° elbow 60/100
EKFGP4660
90° elbow 80/125
EKFGP4810
45° elbow 60/100
EKFGP4661
45° elbow 80/125
EKFGP4811
30° elbow 60/100
EKFGP4664
30° elbow 80/125
EKFGP4814
Extension duct 60/100
500 mm
EKFGP4651
1000 mm
EKFGP4652
Extension duct 80/125
500 mm
EKFGP4801
1000 mm
EKFGP4802
Flue part
Order code
Tile roof outlet kit 60/100
18°/22°
EKFGS0518
23°/27°
EKFGS0519
25°/45°
EKFGP7910
43°/47°
EKFGS0523
48°/52°
EKFGS0524
53°/57
EKFGS0525
Tile roof outlet kit 80/125
18°/22°
EKFGT6300
23°/27°
EKFGT6301
25°/45°
EKFGP7909
43°/47°
EKFGT6305
48°/52°
EKFGT6306
53°/57°
EKFGT6307
Flat roof outlet kit
60/100
EKFGP6940
80/125
EKFGW5333
Wall bracket
DN.100
EKFGP4631
DN.125
EKFGP4481
60/100 to 80/125 adapter
DRDECO80125BA
Tee flex boiler connection set
100 mm
EKFGP6368
130 mm
EKFGP6215
Flex + support elbow
60/100
EKFGP6354
60/130
EKFGS0257
Chimney connection
60/100
EKFGP4678
80/125
EKFGS4828
Roof terminal kit 80 mm
EKFGP6864
90° elbow 80 mm
EKFGW4085
45° elbow 80 mm
EKFGW4086
Extension duct 80 mm
500 mm
EKFGW4001
1000 mm
EKFGW4002
2000 mm
EKFGW4004
60/100 to 80/80 adapter
DRDECOP8080BA
Air intake 80 mm (C53 kit)
EKFGV1102
Air intake 80 mm (C83 kit)
EKFGV1101
Flex kit PP DN.80 (C93 kit)
EKFGP2520
Flex kit PP DN.60/80 (C93 kit)
EKFGP1856
Extension flex PP 80 mm
10 m
EKFGP6340
15 m
EKFGP6344
25 m
EKFGP6341
50 m
EKFGP6342
Connector flex - flex PP 80
EKFGP6324
Spacer PP 80 to 100 mm
EKFGP6333
90° elbow 60 mm
DR90ELBOW60AA
45° elbow 60 mm
DR45ELBOW60AA
Extension duct 60 mm
500 mm
DREXDUC0500AA
1000 mm
DREXDUC1000AA
4.9
To fill the system with water
CAUTION
Water filling must be done while the boiler is in standby
mode.
Method 1
(For
models
D2TND012A4AB,
D2TND018A4AB
and
D2TND024A4AB)
Summary of Contents for D2CND024A4AB
Page 31: ......