3 Operation

Operation manual

4

D2CND024A1/4AB + D2TND012~024A4AB

Wall-mounted condensing boiler

3P469438-3M – 2019.11

3

Operation

3.1

User interface

a

e

f

g

c

b

d

a

Left dial

b

LCD screen

c

Right dial

d

Mode / Reset

e

Status indicator

f

Cancel / Back

g

Menu / Enter

3.1.1

Buttons and dials

The  three  buttons  and  two  dials  on  the  user  interface  have  various
functions  according  to  different  situations,  which  are  stated  in  the
table below:

Button/Dial

Function

Description

Mode /
Reset

Mode

Change mode between summer,
winter, central heating only, standby
and full-off.

Reset

Reset the lockout error.

Cancel /
Back

Cancel

Cancel changes.

Back

Go back to the parent menu.

Menu / Enter Menu

Enter the menu function.

Enter

Passing on to the next level in the
menu structure.

Confirm

Confirmation of changes.

Left dial

User
interaction
level

Central heating temperature setpoint.

This is either the central heating flow
temperature, the room temperature,
or the virtual room temperature,
depending on the system
configuration.

Menu level

Selection of info, user, service menu.

Right dial

User
interaction
level

Domestic hot water temperature
setpoint.

Menu level

▪ Selection parameter index.

▪ Change parameter values.

3.1.2

LCD screen

LCD  screen  is  the  monitor  of  the  user  interface.  You  can  see  the
boiler  operation  mode,  setpoints,  information  about  actuators  and
menu parameters on this screen.

The  LCD  screen  has  a  sleeping  function.  After  one  minute  of  non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.

When you interact with the user interface, the LCD screen will show
the  home  screen  of  the  active  operation  mode  and  the  related
setpoint, depending on the system configuration (see 

"3.3.3 Possible

operation modes"

 [

4

 5]).

Status icons

Meaning of icons that appear on the LCD screen:

Icon

Description

Operation mode: Standby mode

Domestic hot water operation enabled

Domestic hot water comfort mode is enabled

Central heating operation enabled

Room temperature

Outdoor sensor connection

Central heating ECO mode enabled

Flame

Info menu

User settings menu

Service settings menu

3.1.3

Status indicator

The status indicator gives first level feedback on the operation mode
and status of the boiler.

Status

Description

Standby

When there is no heat demand, the status
indicator shows this with a kind of breathing
pulsation of the blue and white LED.

Flame

At the moment flame ignites for central heating or
domestic hot water, the ring flashes to its
maximum, then constantly keeps glowing during
burner operation.

Error

The status indicator will go into error mode when a
warning, lockout or blocking error occurs (see

"3.4 Error handling"

 [

4

 7]). During the error

condition the status indicator continuously shows
the red blinking LED.

NOTICE

In  warning  error,  the  status  indicator  colour  turns  to  blue
while the boiler is operating.

3.2

Operating the unit

3.2.1

To switch the unit ON

1

Connect the unit to the main power supply.

2

Press the "Mode" button for 5 seconds to switch ON the unit.

3

After  that,  you  can  select  an  operation  mode  by  pressing  the
"Mode" button shortly.

Use of the unit is explained in following parts of this manual.

3.2.2

About the low water temperature function

The  low  water  temperature  function  is  a  safety  function  that  takes
place  at  first  central  heating  operation  after  each  power  supply
interruption and at first central heating operation after each 90 days.

Summary of Contents for D2CND-A1A

Page 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler D2CND024A1AB D2CND024A4AB D2TND012A4AB D2TND018A4AB D2TND024A4AB ...

Page 2: ...ndensing boiler that can supply heat to central heating systems as well as supply domestic hot water Depending on settings it is possible to use the unit solely for hot water or solely for central heating Hot water supply type can be instantaneous or by means of a hot water storage tank Heating only boilers do not supply domestic hot water The type of the boiler can be recognised from the model na...

Page 3: ...ever attempt to perform maintenance or repair yourself Call a qualified service agent CAUTION Do not use sprays solvents chlorinated cleaning agents paint and adhesives in the vicinity of the unit These substances can cause corrosion even in the flue system DANGER Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modificat...

Page 4: ...show the home screen of the active operation mode and the related setpoint depending on the system configuration see 3 3 3 Possible operation modes 45 Status icons Meaning of icons that appear on the LCD screen Icon Description Operation mode Standby mode Domestic hot water operation enabled Domestic hot water comfort mode is enabled Central heating operation enabled Room temperature Outdoor senso...

Page 5: ...mode c Summer mode d Winter mode e Full off mode 3 3 3 Possible operation modes Operation mode Description Central heating only mode Only central heating operation mode is enabled The central heating temperature setpoint which setpoint is shown depends on the system configuration see 3 3 5 Possible central heating operation modes 4 6 and the icon is shown on the home screen The icon blinks if cent...

Page 6: ...oom temperature is displayed The room temperature setpoint can be adjusted from the user interface by means of the left dial or from the Daikin room thermostat The icon is shown on the screen instead of the icon when central heating operation mode is enabled Boiler outdoor sensor Weather compensation The case that outdoor sensor is connected to the boiler In this case the central heating water tem...

Page 7: ...ion the unit must be connected to the power supply and its main gas valve must be open Any damage caused by frost is not covered by the warranty Frost Protection is enabled in all modes including standby mode and full off mode While frost protection is active Fr and actual flow temperature are displayed subsequently on the display WARNING If the boiler is not connected to the power supply frost pr...

Page 8: ...l energy consumption Central Heating Last month kWh Description short Unit F12 d Fuel energy consumption Central Heating Current month kWh F13 d Fuel energy consumption Central Heating Current Year kWh F21 d Electric energy consumption Central Heating Last month kWh F22 d Electric energy consumption Central Heating Current month kWh F23 d Electric energy consumption Central Heating Current Year kW...

Page 9: ...value same function that can be done via the right dial when domestic hot water mode is enabled U05 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there is a heat demand U06 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there i...

Page 10: ...Do not let your room become too hot Decreasing the room temperature during the day saves energy Have your combi boiler s maintenance performed at least annually Provide your building with sufficient heat insulation Thermostatic valves should be used Each room should be adjusted according to comfort conditions For reception rooms this is 20 C living rooms 22 C kitchens 18 C and bedrooms 18 C Preven...

Page 11: ...E1 73 Internal PCB error Perform reset if needed If problem repeats contact your service agent H9 01 Outside sensor fault Boiler continues operation but outside sensor is defective Contact your service agent HC 01 Domestic hot water temperature sensor fault Boiler continues operation but you must contact your service agent HJ 08 High system pressure Discharge water down to 0 8 bar You can bleed th...

Page 12: ...who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference GAS BOILER SYSTEM COMMISSIONING CHECKLIST CONTROLS Programmable room thermostat Optimum start control Combination Boiler Fitted Fitted Fitted Automatic bypass to system Fitted Boiler interlock ALL SYSTEMS Yes Yes CENTRAL HEATING M...

Page 13: ...It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed Service Provider SERVICE RECORD SERVICE 01 AND Where Possible AND Signature SERVICE 02 AND Where Possible AND Signature SERVICE 03 AND Where Possible AND Signature SERVICE 04 AND Where Possible AND Signature SERVICE 05 AND Where Possible AND Signature SERVICE 06 AND Where ...

Page 14: ......