English
34
1.
Take off the titanium
apatite photocatalytic air-
purifying fi lter.
• Open the front panel and pull out the air fi lters.
• Hold the recessed parts of the frame and unhook
the 4 claws.
Claw
2.
Clean or replace the titanium
apatite photocatalytic air-
purifying fi lter.
[Maintenance]
2-1 Vacuum dusts, and soak in
lukewarm water or water for about
10 to 15 minutes if dirt is heavy.
• Do not remove the fi lter from frame when
washing with water.
2-2 After washing, shake off remaining
water and dry in the shade.
• Since the material is made out of polyester, do
not wring out the fi lter when removing water from
it.
[Replacement]
Remove the tabs on the fi lter
frame and replace with a new
fi lter.
• Do not throw away the fi lter frame. Reuse the
fi lter frame when replacing the titanium apatite
photocatalytic air-purifying fi lter.
• Dispose of the old fi lter as non-fl ammable waste.
3.
Set the fi lters as they were
and close the front panel.
• Press the front panel at both sides and the
center.
NOTE
• Operation with dirty fi lters:
– cannot deodorize the air,
– cannot clean the air,
– results in poor heating or cooling,
– may cause odour.
• Dispose of old fi lters as non-fl ammable waste.
• To order titanium apatite photocatalytic air-purifying
fi lter contact to the service shop there you bought the
air conditioner.
Item
Titanium apatite photocatalytic
air-purifying fi lter (without frame) 1 set
Part No.
KAF970A46
■
Titanium apatite photocatalytic air-purifying fi lter
01_EN_3P297033-1.indd 34
10/12/2011 2:15:34 PM