Page 1: ...Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel INSTALLATION MANUAL BYCQ140E2GW1 BYCQ140E2GFW1 BYCQ140E2GFW1B...
Page 2: ...ag may be suffocated CAUTION Install the indoor and outdoor units power cord remote controller wiring and transmission wiring at least 1 m away from TV or radio sets This is for the prevention of TV a...
Page 3: ...mer Did you deliver the operation manual to the customer Be sure to hand the customer the operation manual as well as the installation manual Did you hand the customer the connecting pipe and attachme...
Page 4: ...top of the panel together with the accessories attached to the backside of the protective corrugated cardboard Protective corrugated cardboard top The accessories are on the backside Protective corrug...
Page 5: ...an electric shock may be received CAUTION Conduct the following work after installing the indoor unit Install the indoor unit according to the installation manual provided with the indoor unit 5 1 Att...
Page 6: ...l 1 Tentatively put the two temporary latching brackets of the suction port of the panel on the internal circumference side to the hooks of the indoor unit Note Remove your hands after confirming thro...
Page 7: ...tallation manual of the indoor unit to conduct the work 6 3 Checking panel 1 Remove sealing of panel 1 2 1 2 3 4 1 Remove seal of panel 2 Insert the seal until the seal comes in contact with the claw...
Page 8: ...own in the illustration 1 2 3 4 5 1 Clasp 2 Hooked fall prevention cord 3 Panel 4 Fall prevention cord 5 Dust box 2 Attach the dust box in the order opposite to the procedure in 4 3 Removal of dust bo...
Page 9: ...e Clasp Fall prevention cord Clasp Bend the clasp inward Fall prevention cord 3 Connect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint...
Page 10: ...rd 3 Connect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint Flexible hose junction on the panel side Fit the claws into the hooks in t...
Page 11: ...selected for the filter auto cleaning of the self clean panel Operation mode Description 1 Scheduled timer operation Performs filter auto cleaning during the designated period selected from eight per...
Page 12: ...ion after the power is turned on 10 3 Conduct the test operation of the panel two minutes after the power is turned on Confirm the cleaning operation of the filter with the remote controller Test oper...