OPERATING INDICATOR LAMP (Red)

This lamp stays lit while the air 
conditioner runs. It flashes when the 
unit is in trouble.

21

TIMER INDICATOR LAMP (Green)

This lamp stays lit while the timer is set.

22

AIR FILTER CLEANING TIME 
INDICATOR LAMP (Red)

Lights up when it is time to clean the air 
filter.

23

DEFROST LAMP (Orange)

Lights up when the defrosting opera-
tion has started. (For cooling  only type 
this lamp does not turn on.)

24

FAN/AIR CONDITIONING SELECTOR 
SWITCH

Set the switch to “

” (FAN) for FAN 

and “

” (A/C) for HEAT or COOL.

25

COOL/HEAT CHANGEOVER SWITCH

Set the switch to “

” (COOL) for 

COOL and “

” (HEAT) for HEAT.

NOTES

For the sake of explanation, all indica-
tions are shown on the display in Figure 1 
contrary to actual running situations.

Fig. 1-2 shows the remote controller with 
the front cover opened.

Fig. 1-3 shows this remote controller can 
be used in conjunction with the one pro-
vided with the VRV system.

If the air filter cleaning time indicator lamp 
lights up, clean the air filter as explained 
in the operation manual provided with the 
indoor unit.
After cleaning and reinstalling the air fil-
ter, press the filter sign reset button on 
the remote controller.  The air filter clean-
ing time indicator lamp on the receiver will 
go out.

The Defrost Lamp will flash when the power 
is turned on. This is not a malfunction.

Precautions in handling remote con-
troller

Direct the transmitting part of the remote 
controller to the receiving part of the air 
conditioner.

If something blocks the transmitting and receiv-
ing path of the indoor unit and the remote con-
troller as curtains, it will not operate.

Transmitting distance is approximately 7 m.

Do not drop or get it wet.

It may be damaged.

Never press the button of the remote con-
troller with a hard, pointed object.

The remote controller may be damaged.

Installation site

It is possible that signals will not be received 
in rooms that have electronic fluorescent 
lighting. Please consult with the salesman 
before buying new fluorescent lights.

If the remote controller operated some 
other electrical apparatus, move that 
machine away or consult your dealer.

3. HANDLING FOR 

WIRELESS REMOTE 
CONTROLLER

2 short beeps 
from the receiver 
indicates that the 
transmission is 
properly done.

Summary of Contents for BRC7E61W

Page 1: ...ow to use the unit properly and help you if any trouble occurs After reading the manual file it away for future reference Le agradecemos la compra de este acondicionador de aire Daikin Lea cuidadosame...

Page 2: ......

Page 3: ...3 11 12 15 14 16 17 9 1 3 4 6 2 5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr hr TEST 24 25 COOL HEAT CHANGEOVER REMOTE CONTROL...

Page 4: ...on manual attached to the indoor unit for safe usage of the system and maintenance ANTES DE LA UTILIZACI N Este manual de instrucciones contiene s lo las instrucciones para el uso del control remoto s...

Page 5: ...ire turn off the power and con tact your dealer for instructions If you keep using the air conditioner under these conditions it will eventually break down and could cause electric shocks or catch fir...

Page 6: ...r TEST 8 ON OFF BUTTON Press the button and the system will start Press the button again and the system will stop 9 FAN SPEED CONTROL BUTTON Press this button to select the fan speed HIGH or LOW of yo...

Page 7: ...ion manual provided with the indoor unit After cleaning and reinstalling the air fil ter press the filter sign reset button on the remote controller The air filter clean ing time indicator lamp on the...

Page 8: ...older Removing the remote controller Pull it upward In case the remote controller is not used for a long time take out all batteries in order to prevent liquid leak of the battery IN THE CASE OF CENTR...

Page 9: ...eral times and select the OPERATION MODE of your choice as follows COOLING OPERATION HEATING OPERATION 5 OPERATION PROCEDURE COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION 1 MODE AUTOMATIC OP...

Page 10: ...ater at the same time as this air conditioner 2 ON OFF Hot air is circulated to warm the room It will take some time from when the air con ditioner is first started until the entire room becomes warm...

Page 11: ...facing downward air flow direction may change unexpectedly There is nothing wrong with the equipment This serves to prevent dew formed on parts in the air discharge outlet from dripping Operation mod...

Page 12: ...system after 4 hours the system will stop after 3 hours and then 1 hour later the system will start After the timer is programmed the display shows the remaining time 2 DOWN UP DOWN UP 3 RESERVE 4 CA...

Page 13: ...ted as the master remote controller and the display showing van ishes To change settings repeat steps and EMERGENCY OPERATION When the remote controller does not work due to battery failure or the abs...

Page 14: ...ately because a safety device operates to prevent overload of the system After 3 minutes the system will turn on again automatically If the reception beep is rapidly repeated 3 times It sounds only tw...

Page 15: ...to get the display back to the normal state MODE 3 4 DOWN UP 5 MODE 6 DOWN UP 7 MODE II IN CASE BESIDES EMERGENCY STOP 1 The unit does not operate at all Check if the receiver is exposed of sunlight...

Page 16: ...y and contact the place of purchase Using the equipment in anything but proper working condition can result in equipment damage electric shock and or fire Trouble The RUN lamp of the indoor unit is fl...

Page 17: ...3P107422 12L EM01A116A 0701 HT FS...

Reviews: