background image

Wired Remote 

Controller

Installation Manual

MODEL  BRC1H61W/BRC1H61K

+

-

• Be sure to read before conducting the installation of this product, and conduct 

installation according to this manual.

• Refer to this manual together with the installation manual of the indoor unit.

It is possible to perform settings of some functions from  

a smart phone app.

00_CV_EM19A034_IM.indd   1

2020/09/02   15:54:02

Summary of Contents for BRC1H61K

Page 1: ...conducting the installation of this product and conduct installation according to this manual Refer to this manual together with the installation manual of the indoor unit It is possible to perform settings of some functions from a smart phone app 00_CV_EM19A034_IM indd 1 2020 09 02 15 54 02 ...

Page 2: ...view of screens 12 Setting screen list 13 Names and Functions 15 Starting up the system 16 Switching the Changeover Master 19 Installer Menu 23 Field Setting 24 R C Setting 31 Installer Password Setting 34 Other Service Settings 35 External input interlock 36 License 42 Certification 43 01_EN_EM19A034_IM indd 1 2020 09 02 15 53 12 ...

Page 3: ...esult in electric shocks or a fire Be sure to use only the specified accessories and parts for installation work Failure to use the specified parts may result in the remote controller falling down electric shocks or a fire Install the remote controller on a foundation that can withstand its mass Insufficient strength may result in the remote controller falling down and causing injury Make certain ...

Page 4: ...d cause a malfunction of the equipment 4 Where flammable gas may leak where there is carbon fibre or ignitable dust suspensions in the air or where volatile flammables such as thinner or gasoline are handled Operating the unit in such conditions may result in a fire 5 High temperature area or directly flamed point It may cause an overheat or a fire 6 Moist area or place where may be exposed to wat...

Page 5: ... be seen after the remote controller is installed NOTE 3 11 64 80 5 13 64 5 33 64 13 1 47 64 44 9 32 7 R3 32 2 5 R3 32 2 5 13 64 5 41 64 16 25 1 47 64 44 35 64 13 75 3 11 64 80 5 Back plate Through hole Align the centre of the wall hole with the centre of the access hole on the controller back plate when planning the installation Access hole Unit inch mm Back plate Through hole Access hole CAUTION...

Page 6: ...a piece of the back plate according to the following figure After removing a thin piece with a tool such as clippers remove burrs using a file etc a Wiring from top b Wiring from left c Wiring from bottom a b c CAUTION In case you are routing the wiring from the rear you don t have to remove anything When routing the wiring from the top rear left or bottom be sure to route the wiring to the upper ...

Page 7: ...d head wood screws Drywall anchors CAUTION Install the controller on a flat surface only To prevent deformation of the back plate avoid over tightening the installation screws If tightened too much the back plate will be deformed and the upper casing will come off easily If the upper casing comes off easily loosen the screws and correct the deformation 01_EN_EM19A034_IM indd 6 2020 09 02 15 53 13 ...

Page 8: ...g maintain a 3 8 inch 10 mm difference between the length of the two conductors Cutting guideline L Wiring outlet L Top 5 5 inch 140 mm Left 4 3 inch 110 mm Bottom 3 5 inch 90 mm Rear No requirements Connect the terminals P1 P2 of the remote controller to the terminals P1 P2 of the indoor unit P1 and P2 are not polarity sensitive CAUTION Before working shut off all power supplies A mounting plate ...

Page 9: ...8 Top outlet P1P2 P1P2 terminal Rear outlet P1P2 Left outlet P1P2 01_EN_EM19A034_IM indd 8 2020 09 02 15 53 13 ...

Page 10: ...e top of the controller on the top of the back plate 2 Snap the bottom of the controller into place on the bottom of the back plate 3 Ensure the installation site is dust free before peeling the protective seal 1 2 CAUTION Never touch the internal parts of the controller When closing the controller be careful not to pinch the wiring To prevent damage make sure the front of the controller is clicke...

Page 11: ...troller circuit board is attached to the upper casing Be careful not to damage the circuit board and casing when removing the upper casing Do not touch the remote controller circuit board directly with your hands Be careful not to allow dust or moisture to adhere to the circuit board when the upper casing is removed 01_EN_EM19A034_IM indd 10 2020 09 02 15 53 14 ...

Page 12: ...this button again to turn off the system b Status indicator LED During operation the light ring around the display lights up blue red green Lights up blue Operating Blinks red Error is occurring Lights up blinks green Bluetooth connecting c LCD Refer to INFORMATION on page 15 Displays the current setpoint and air conditioner operation status d NAVIGATE ADJUST button Navigate right Adjust a setting...

Page 13: ...menu Information screen Installer menu This screen is a menu for the administrator See the next page for items which can be selected 12 34 A3 01 Unit 00 This screen displays the time and the status of the remote controller and the system If an error occurs the error code is displayed This screen is a menu for the installer See the next page for items which can be selected Press and hold for 5 seco...

Page 14: ...urrent setting Vertical Airflow Airflow direction 2 setting Depends on current setting Ventilation Mode Ventilation mode setting Depends on current setting Ventilation Rate Ventilation rate setting Adjust LED ON LED brightness adjustment when backlight lights up Adjust LED OFF LED brightness adjustment when backlight lights up dimly Sign Reset Filter sign reset Celsius Fahrenheit Fahrenheit Celsiu...

Page 15: ...st setting Clock Setting Clock setting About Administrator information Admin Password Administrator password setting Installer Password Installer password setting Field Setting Field Setting R C Setting R C Setting Address Setting Address Setting Forced Fan ON Forced Fan ON Setting Rel Master Control Release changeover master 01_EN_EM19A034_IM indd 14 2020 09 02 15 53 16 ...

Page 16: ... h Bluetooth Indicates that the controller is communicating with a mobile device for use with the app i Changeover Under Control Displayed when controller is unauthorized to select heating cooling operation j Fahrenheit Celsius Depending on the setting Fahrenheit Celsius display can be selected k Air Purifying l Set temperature Displays setpoint temperature m Clock 24 hours time display n MAIN SUB...

Page 17: ...atically start up If it is the first and only controller that is connected to the indoor unit it will automatically get designated as the main controller If there is a second controller it is necessary to manually set it as a sub controller Main and sub controller a b c d a Outdoor unit b Indoor unit c Main remote controller d Sub remote controller On the information screen main sub status is indi...

Page 18: ...ORMATION If a sub controller does not display the home screen 2 minutes after its designation turn off the power and check the wiring INFORMATION After re designating a controller the system requires a power reset INFORMATION The following functions are not available for sub controllers Auto operation mode Individual airflow direction Filter auto clean Setback temperature setpoints Draft preventio...

Page 19: ...code appears press and hold until 2 appears on the screen When the U8 error code appears press and hold until 1 appears on the screen Result A controller displaying 1 is set as main and a controller displaying 2 is set as sub INFORMATION If sub remote controller is not set at power on in the case of one indoor unit controlled by two remote controllers Error Code U5 is displayed in the connection c...

Page 20: ...as the changeover master Depending on the system this function may not be available Possible operation mode selections for a remote controller that is a changeover master or a mode follower Operation modes for the remote controller that is a changeover master Operation modes that can be selected by remote controllers that is a mode follower Heating via Heat Auto Heat Fan Cooling via Cool Auto Cool...

Page 21: ...em When multiple indoor units are connected to the same port of a branch selector unit Give the authority to choose cooling heating or auto to 1 of these remote controllers c c b b c d c b b d d a e f e e a Outdoor unit b Indoor unit c Remote controller d Branch selector unit This unit switches between cooling and heating e Changeover master f Changeover mode follower The screen of the remote cont...

Page 22: ...uisite You are in the installer menu You are operating the controller of the indoor unit that you want to release from being the changeover master Home screen 30 C 28 Press and hold button for 5 seconds or longer The information screen is displayed Information screen 12 34 Press in that order and hold them down for 10 seconds The installer menu screen is displayed Installer menu screen Navigate to...

Page 23: ...eover master This setting is available only when none of the remote control in the system has master control Prerequisite No indoor unit is yet set as the changeover master icon blinking on all controllers You are operating the controller of the indoor unit that you want to set as the changeover master 30 C 28 Menu screen Navigate to Sub menu screen Press or 01_EN_EM19A034_IM indd 22 2020 09 02 15...

Page 24: ...staller Menu How to enter the Installer menu Installer menu screen Home screen 30 C 28 C Press and hold button for 5 seconds or longer to display the information screen Information screen 12 34 Press in that order and hold them down for 10 seconds The installer menu screen is displayed 01_EN_EM19A034_IM indd 23 2020 09 02 15 53 18 ...

Page 25: ...ntroller side is impossible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen Mode 20 Unit 00 a b Press or button to select Mode No and press to enter the field setting menu a Mode No b Unit No Sub menu screen Mode 20 Unit 00 Press or button to scroll the desired Mode No and press button Sub menu screen Mode 20 Unit 00 Press or button to select Unit No and p...

Page 26: ...0 Press or button to select and then press button to set the selection Sub menu screen SW 00 01 a b Press or button select First Code No and then press button a First Code No b Second Code No Sub menu screen SW 00 01 Press or button scroll to the desired First code No and then press button to set the selection 01_EN_EM19A034_IM indd 25 2020 09 02 15 53 20 ...

Page 27: ... 00 01 Press or button select and then press button to save the setting and return to the previous screen If the setting is not changed select Sub menu screen Mode 20 Unit 00 Press or button move to and then press button to return to the installer menu If the setting has been changed the screen may return to the home screen without returning to the installer menu 01_EN_EM19A034_IM indd 26 2020 09 ...

Page 28: ...or details about the specific field settings of each type of indoor unit see the installation manual of the indoor unit Field settings that are not available for a connected indoor unit are not displayed Field setting default values are different depending on the indoor unit model For more information see the service manual of the indoor units 01_EN_EM19A034_IM indd 27 2020 09 02 15 53 20 ...

Page 29: ...x 5 000 hrs Long life filter Approx 2 500 hrs Approx 1 250 hrs Standard filter Approx 200 hrs Approx 100 hrs 1 Long life filter type Setting of filter sign indication time Change setting when Ultra long life filter is installed Long life filter Ultra long life filter 2 Thermostat sensor in remote controller Use Not use 3 Spacing time of display time to clean air filter count Setting for when the f...

Page 30: ...direction range setting Upper Normal Lower 6 Setting the external static pressure Setting according to the connected duct resistance Normal High static pressure Low static pressure For FHYK Normal High ceiling 15 25 3 Drain pump operation with humidifying Equipped Not equipped 1B 08 Daylight savings time setting Disabled Change at fixed time Change on individual remote controllers manually Change ...

Page 31: ...ry shipment is set to 01 However for the following cases it is not 01 Airflow direction range setting except Round flow cassette 02 Thermostat sensor in remote controller SPLIT system only 02 Thermostat sensor in remote controller for auto mode and Setback function only 02 Setback function 04 3 Any function which the indoor unit does not have is not displayed 01_EN_EM19A034_IM indd 30 2020 09 02 1...

Page 32: ...de is impossible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen Mode R1 Unit a b Press or button to select Mode No and press to enter the field setting menu a Mode No b Unit No Sub menu screen Mode R3 Unit Press or button to scroll to the desired Mode No and press button Sub menu screen Mode R3 Unit Press or button to select and then press button to set t...

Page 33: ...en SW 13 00 Press or button scroll to the desired First code No and then press button to set the selection Sub menu screen SW 13 00 Press or button to move Second Code No and then press button Sub menu screen SW 13 00 Press or button scroll to the desired Second code No and then press button 01_EN_EM19A034_IM indd 32 2020 09 02 15 53 22 ...

Page 34: ... the installer menu If the setting has been changed the screen may return to the home screen without returning to the installer menu R C setting mode list Mode No FIRST CODE NO Description SECOND CODE NO Items in bold are factory default settings 01 02 03 04 05 R1 11 LED lighting settings during error Error blinking Normal continuously lit R1 12 Enable and disable Bluetooth function Disabled Enabl...

Page 35: ...sible Disconnect Bluetooth or perform field setting from the mobile application Sub menu screen 0 0 0 0 a b Press or button select Enable Disable and press to perform password enable disable setting a Enable Disable b Password Sub menu screen 0 0 0 0 Press or button change the password to enable disable and press button Select to enable the password and select to disable the password Sub menu scre...

Page 36: ... 1 2 3 4 Press or button move to and then press button to return to the installer menu Other Service Settings Group Address Assign the group address and unit number for centralized control The group and unit address can only be set when a centralized controller is connected This menu is only visible when a centralized controller is connected The group and unit address can be set and released NOTIC...

Page 37: ... not function properly the external input interlock menu is not available in the installer menu In case a centralised controller is additionally part of the system external input interlock is controlled by the centralised controller The digital input adapter is then overruled To make external input interlock settings Prerequisite You are in the installer menu 1 Navigate to the external input inter...

Page 38: ...hat starts as soon as the Delay Timer expires When this timer expires the previous state i e regular setpoint changes to the Default Reset Setting state 0 20 hours 20 hours Reset ON OFF ON OFF Default Reset Setting on off state ON OFF OFF Reset Mode Default Reset Setting operation mode Auto Cooling Heating Fan only Reset Cool SP 22 Default Reset Setting cooling setpoint See indoor unit s setpoint ...

Page 39: ...urrent active value is kept Window contact logic Window contact B1 Key card contact B2 Time Action Contact closed window open Contact closed key card IN Normal indoor unit operation The unit returns to the previous state before opening the contact Contact open window open Contact closed key card IN Unit operation is forced off No delay and reset timer functionality No Setback functionality Not pos...

Page 40: ... Setback function is enabled Setback will work or not Not possible to turn on off the unit with the controller s ON OFF button After the delay timer has expired the reset timer will start counting INFORMATION The previous state can be the on off state operation mode cooling setpoint and heating setpoint When using the contacts the fan speed as well as the Setback cooling and heating setpoints can ...

Page 41: ...e Example 1 1 You remove the key card Result The indoor unit continues operating normally until the delay timer expires 2 You open the window before the delay timer expires Result The indoor unit stops immediately It is not possible to turn the unit on or off the Setback functionality does not work the delay timer stops counting and the reset timer starts counting 3 You insert the key card again R...

Page 42: ...ng the window the reset timer will have started counting Closing the window has no influence on the reset timer IF the delay timer HAS NOT expired before closing the window it will expire immediately and the reset timer will start counting When the reset timer expires the previous state is updated to the Default Reset Setting state 4 You insert the key card again Result IF the reset timer HAS NOT ...

Page 43: ...ribution THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT...

Page 44: ...264C For model BRC1H61K ESD RCE 2022819 In Singapore For model BRC1H61W Complies with IMDA Standards N1740 20 For model BRC1H61K Complies with IMDA Standards N1739 20 In Taiwan For model BRC1H61W For model BRC1H61K 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療...

Page 45: ...C1H61W Certificate of conformity number 283 CN TT2 For model BRC1H61K Certificate of conformity number 280 CN TT2 DAIKIN Air Conditioning VietNam Joint Stock Company In Australia In New Zealand 01_EN_EM19A034_IM indd 44 2020 09 02 15 53 25 ...

Page 46: ...EM19A034 2009 HT 00_CV_EM19A034_IM indd 2 2020 09 02 15 54 02 ...