Daikin BEV Series Installation Manual Download Page 1

READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.

LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L’INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.

LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER 
ALGUNA DUDA.

PRIMA DELL’INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.

Ä

ΙΑΒΑΣΤΕ

 

ΠΡΟΣΕΚΤΙΚΑ

 

ΑΥΤΕΣ

 

ΤΙΣ

 

Ο

Ä

ΗΓΙΕΣ

 

ΠΡΙΝ

 

ΑΠΟ

 

ΤΗΝ

 

ΕΓΚΑΤΑΣΤΑΣΗ

 

ΕΧΕΤΕ

 

ΑΥΤΟ

 

ΤΟ

 

ΕΓΧΕΙΡΙ

Ä

ΙΟ

 

ΕΥΚΑΙΡΟ

 

ΓΙΑ

 

ΝΑ

 

ΤΟ

 

ΣΥΜΒΟΥΛΕΥΕΣΤΕ

 

ΣΤΟ

 

ΜΕΛΛΟΝ

.

LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.

LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.

ПЕРЕД

 

НАЧАЛОМ

 

МОНТАЖА

 

ВНИМАТЕЛЬНО

 

ОЗНАКОМЬТЕСЬ

 

С

 

ДАННЫМИ

 

ИНСТРУКЦИЯМИ

СОХРАНИТЕ

 

ДАННОЕ

 

РУКОВОДСТВО

 

В

 

МЕСТЕ

УДОБНОМ

 

ДЛЯ

 

ОБРАЩЕНИЯ

 

В

 

БУДУЩЕМ

.

English

MODELS

BEV unit

BEVQ50MVE

Deutsch

Français

Español

Italiano

Ελληνικ

Ü

Nederlands

Portugues

Russian

SYSTEM Inverter Air Conditioners

INSTALLATION MANUAL

3P084604-3C_cv.fm  Page 1  Monday, June 7, 2004  10:14 AM

Summary of Contents for BEV Series

Page 1: ...EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA PRIMA DELL INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI LEES DEZE INST...

Page 2: ...FXLQ63MVE FXNQ20MVE FXNQ25MVE FXNQ32MVE FXNQ40MVE FXNQ50MVE FXNQ63MVE FXHQ32MVE FXHQ63MVE FXHQ100MVE FXSQ20MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVE FXSQ80MVE FXSQ100MVE FXSQ125MVE FXKQ25...

Page 3: ...Failure to observe a warning may result in death CAUTION Failure to observe a caution may result in injury or damage to the unit WARNING Ask your dealer or qualified personnel to carry out installatio...

Page 4: ...piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wiring at least 1 meter away from televisions or radios in order to prev...

Page 5: ...ike thinner or gasoline is used Gas in the vicinity of the unit could ignite Where machines can generate electromagnetic waves Control system may malfunction Where the air contains high levels of salt...

Page 6: ...ds crossbeams etc 3 Install the gas piping connection piping 7 no further than 250mm form the hole for the thermistor on the unit Refer to the 8 1 HOW TO CONNECT WIRINGS 4 Avoid any contact with the c...

Page 7: ...tall so that the control box lid is facing down Take the gas piping thermistor out from above Horizontal position Direction of the gas piping connection piping 100 Upper Lower 100 250 or more 500 or m...

Page 8: ...stall the hanging bolts Use M8 hanging bolts If it is pre set use hole in anchors Otherwise use embedded inserts or embedded foundation bolts to make sure that the weight of the unit can be supported...

Page 9: ...h tape Do not allow anything other than the designated refrigerant to get mixed into the refrigerant circuit such as air etc If any refrigerant gas leaks while working on the unit ventilate the room t...

Page 10: ...necting section after checking gas leakage by thoroughly studying the following figure Wrap the insulation for fitting 3 4 around the insulation for the joints on the liquid piping side and the gas pi...

Page 11: ...razing after having carried out nitrogen substitution or while inserting nitrogen into the refrigerant piping Once this is done connect the indoor unit with a flared connection Nitrogen should be set...

Page 12: ...Additional filling amount a b c d e f g h i j k l m n p q Refer also to the installation manual included with the outdoor unit 7 ELECTRIC WIRING WORK 7 1 GENERAL INSTRUCTIONS All field supplied parts...

Page 13: ...otor Rated Output kW FLA Full Load Amps A NOTES The above Table of Electrical Characteristics refers to the BEV and Indoor unit See the technical documents for other details 7 3 SPECIFICATIONS FOR FIE...

Page 14: ...e and the transmission wiring using the included clamp 1 CAUTIONS Do not under any circumstances connect the power supply wiring to the transmission terminal block F1 F2 as this may cause damage to th...

Page 15: ...t wiring ground wire and other power wiring The equipment may malfunction if subjected to electrical external noise 5 For remote controller wiring refer to the INSTALLATION MANUAL OF REMOTE CONTROLLER...

Page 16: ...Remote controller Remote controller Remote controller Remote controller When calculating the limit of connected indoor units count all the lower BEV units as one unit If the remote controller does no...

Page 17: ...ach the included nameplate 9 next to the machine nameplate on the indoor unit 10 TEST OPERATION Make sure the control box lids are closed on the indoor and BEV and outdoor units Refer to the installat...

Page 18: ...0408 HT 3P084604 3C EM04A023 3P084604 3C_cv fm Page 2 Monday June 7 2004 10 14 AM...