Printed Circuit Board Connector Wiring Diagram
SiBE04-809
10
Printed Circuit Board Connector Wiring Diagram
1.2
Outdoor Unit
Connectors
PCB (1) (Filter PCB)
PCB (2) (Control PCB)
Note:
Other designations
PCB (1) (Filter PCB)
PCB (2) (Control PCB)
1)
S11
Connector for control PCB
1)
S10
,
S50
Connector for filter PCB
2)
S20
Connector for electronic expansion valve coil
3)
S30
Connector for compressor motor
4)
S40
Connector for
overload protector
5)
S70
Connector for fan motor
6)
S80
Connector for four way valve coil
7)
S90
Connector for thermistors
(outdoor air, heat exchanger, discharge pipe)
8)
HL3, HN3
Connector for filter PCB
1)
FU3
Fuse (20A)
2)
V2, V3
Varistor
1)
FU1, FU2
Fuse
(3.15A)
2)
LED A
Service monitor LED
3)
V1
Varistor