SiBE04-809
Outdoor Unit
Removal Procedure
177
2.3
Removal of
Reactor
and
Partition Plate
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the outer panels.
Remove the electrical
box.
1. Remove the reactor.
1
Loosen the screw.
Lift and remove the
reactor.
2. Remove the partition
plate.
1
Loosen the 2 screws.
(R7224)
Reactor
(R7225)
(R7226)
Partition plate
Summary of Contents for ARXG25E3V1B