Indoor Unit
SiBE04-809
142
Removal Procedure
1.8
Removal of Vertical Blades and Swing Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the assembly of
the outlet grille.
1. Remove the vertical
blades.
1
Release the 4 hooks
and remove the thermal
insulation.
2
Release the 4 hooks
and remove the thermal
insulation.
Summary of Contents for ARXG25E3V1B