17
|
Technical data
Installer reference guide
258
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
17.3 Wiring diagram: Outdoor unit
The wiring diagram is delivered with the unit, located at the inside of the service
cover.
Compressor module
Translation of text on wiring diagram:
English
Translation
(1) Connection diagram
(1) Connection diagram
Compressor SWB
Compressor switch box
Outdoor
Outdoor
(2) Compressor switch box layout
(2) Compressor switch box layout
Front
Front
Rear
Rear
(3) Legend
(3) Legend
*: Optional; #: Field supply
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
A3P
(only for 1N~ models)
Printed circuit board (flash)
Q1DI
# Earth leakage circuit breaker
X1M
Terminal strip
(4) Notes
(4) Notes
X1M
Main terminal
Earth wiring
Field supply
1
Several wiring possibilities
Option
Wiring depending on model
Switch box
PCB
Hydro module
Translation of text on wiring diagram:
English
Translation
(1) Connection diagram
(1) Connection diagram
3 wire type SPDT
3 wire type SPDT
Booster heater power supply
Booster heater power supply
Compressor switch box
Compressor switch box
External BUH
External backup heater kit
For DHW tank option
For DHW tank option
Summary of Contents for ALTHERMA