4
|
Operation
User reference guide
24
C08AF + EHYKOMB33AA
Daikin Altherma R Hybrid
4P471762-1B – 2020.10
Reheat mode
In reheat mode ( ),the DHW tank continuously heats up to the temperature shown
on the DHW tank temperature home page (example: 50°C).
t
60°C
00:00
07:00
50°C
15°C
40°C
14:00
21:00
1
2
3
4
Tt
T
t
Domestic hot water tank temperature
t
Time
INFORMATION
When the DHW tank mode is reheat, the risk for capacity shortage and comfort
problem is significant. In case of frequent reheat operation, space heating function is
regularly interrupted.
Scheduled mode
In scheduled mode ( ), the DHW tank produces hot water corresponding to a
schedule. The best time to allow the tank to produce hot water is at night, because
the space heating demand is lower.
Example:
t
60°C
00:00
07:00
50°C
15°C
40°C
14:00
21:00
1
2
3
4
5
Tt
T
t
Domestic hot water tank temperature
t
Time
▪
Initially, the DHW tank temperature is the same as the temperature of the
domestic water entering the DHW tank (example:
15°C
).
▪
At 00:00 the DHW tank is programmed to heat up the water to a preset value
(example:
Storage comfort
= 60°C
).
▪
During the morning, you consume hot water and the DHW tank temperature
decreases.
▪
At 14:00 the DHW tank is programmed to heat up the water to a preset value
(example:
Storage eco
=
50°C
). Hot water is available again.
▪
During the afternoon and evening, you consume hot water again and the
DHW tank temperature decreases again.
▪
At 00:00 the next day, the cycle repeats.