12
|
Maintenance and service
Installer reference guide
202
EHYH EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
4
Clean the condensate trap with water.
12.7 To assemble the gas boiler
CAUTION
▪
When fitting the various seals, check them for damage, hardening, tears or
hairline tears, and/or discolouration. Replace them when necessary.
▪
Check the position of the seals.
▪
Not fitting the sensors S1 and/or S2 or fitting them incorrectly can result in
serious damage.
▪
Warranty will be void by NOT correctly replacing the removed parts.
1
Check the correct position of the seal around the front cover.
2
Place the front cover on the heat exchanger and secure by using the socket
head screws plus serrated lock washers.
3
Tighten the socket head screws equally hand-tight by turning the hex key
clockwise.
4
Fit the gas connection below the gas valve.
5
Fit the connector to the fan and the ignition unit to the gas valve.
6
Fit the condensate drain by sliding on the exchanger outlet stump with the
condensate trap connection still in front of the base tray.
a
a
Base tray
7
Turn the condensate drain to the left and push it downwards into the
condensate trap connection. Make sure in doing this that the back of the
condensate drain pan comes to rest on the lug of the back of the base tray.