Removal procedure: outdoor unit ERYQ005~007AAV3
ESIE06-03
5–18
Part 5 – Disassembly and Maintenance
3
1
55
2.5
Removal of the PCB
Warning
Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure
Step
Procedure
Points
P
Remove the electrical box.
1
Remove the PCB.
1
Disconnect the
connectors for the
control PCB (S52,
S102).
2
Undo the 4 clamps by
pliers.
3
Loosen the fixing screw
of the cable way board
and disconnect the
earth wire.
4
Undo the hook on the
right.
Clamps
Earth wire