4
|
Operation
User reference guide
17
EHYH EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
If…
Then the temperature control is…
Main zone
Additional zone (if
any)
Room temperature is listed
under:
[6.1]: >
Information
>
Sensor information
Room thermostat
control.
Go to next step to
check if leaving water
set point and room
temperature set point
are linked.
External room
thermostat control.
Thermostat main A is listed
under:
[6.5]: >
Information
>
Actuators
External room thermostat control.
Else
Leaving water temperature control.
3
Only for room thermostat control: Go to the main leaving water temperature
home page (
LWT main
) and check the following:
Is displayed next to
the set point?
Then leaving water set point and room
temperature set point are…
Yes
NOT linked.
You can set the leaving water set point on the home
page.
No
Linked by their preset values. You can set the preset
values in the menu structure.
4.4.4 Room thermostat control - About room thermostat control
Room thermostat control means that you control the following:
▪
Room temperature of the main zone
▪
Leaving water temperature of the main zone
Room temperature of the main zone
To control the room temperature of the main zone, you can do the following:
You can…
Location
Read out
the actual and desired room
temperature
.
Room temperature home
page
Temporarily overrule
the room temperature
schedule
.
Change the mode
from scheduled to preset value.
If you do this, you also have to define (in the menu
structure):
▪
Preset values
▪
Overrule period (
Temperature lock
)
Room temperature home
page if user profile =
Detailed