General safety precautions
Installer reference guide
13
08CA + EHY EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
CAUTION
▪
Do NOT place any objects or equipment on top of the unit.
▪
Do NOT sit, climb or stand on the unit.
NOTICE
Works executed on the outdoor unit are best done under dry weather conditions to
avoid water ingress.
If you are NOT sure how to install or operate the unit, contact your dealer.
In accordance with the applicable legislation, it might be necessary to provide a
logbook with the product containing at least: information on maintenance, repair
work, results of tests, stand-by periods,…
Also, at least, following information MUST be provided at an accessible place at the
product:
▪
Instructions for shutting down the system in case of an emergency
▪
Name and address of fire department, police and hospital
▪
Name, address and day and night telephone numbers for obtaining service
In Europe, EN378 provides the necessary guidance for this logbook.
For Swiss market, domestic hot water operation should only be prepared in
combination with a tank. Instant domestic hot water by the gas boiler is NOT
allowed. Make the correct settings as described in this manual.
Please follow following Swiss regulations and directives:
▪
SVGW-gas principles G1 for gas installations,
▪
SVGW-gas principles L1 for liquid gas installations,
▪
cautional instances regulations (e.g., fire regulation).
3.1.2 Installation site
▪
Provide sufficient space around the unit for servicing and air circulation.
▪
Make sure the installation site withstands the weight and vibration of the unit.
▪
Make sure the area is well ventilated. Do NOT block any ventilation openings.
▪
Make sure the unit is level.
▪
If the wall on which the unit is mounted is flammable, a non-flammable material
must be placed between the wall and the unit. Do the same for all locations
through which the flue piping passes.
▪
ONLY operate the gas boiler if a sufficient supply of combustion air is ensured. In
case of a concentric air/flue gas system dimensioned according to the
specifications of this manual, this is fulfilled automatically and there are no other
conditions for the equipment installation room. This method of operation applies
exclusively.
▪
Store flammable fluids and materials at least 1 meter away from the gas boiler.
▪
This gas boiler is NOT designed for room air dependent operation.
Do NOT install the unit in the following places:
▪
In potentially explosive atmospheres.
▪
In places where there is machinery that emits electromagnetic waves.
Electromagnetic waves may disturb the control system, and cause malfunction of
the equipment.