• Monobloc • EBHQ011-016AA6W1
• Altherma
TM
• Monobloc
180
2
Specifications
3
2
Refrigerant Oil
Type
Daphne FVC68D
Charged Volume
l
1.0
1.0
1.0
Defrost Method
Pressure equalising
Defrost Control
Sensor for outdoor heat exchanger temperature
Capacity Control Method
Inverter controlled
Safety Devices
High pressure switch
Fan motor thermal protector
Fuse
Notes
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a
relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing
for more information.
Conditions: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
Conditions: Ta 35°C - LWE 7°C (DT = 5°C)
15°-25°C: BUH only, no heat pump operation = during commisioning
including PHE + back-up heater / excluding expansion vessel
E(D)(B)L* model can reach -20°C / E(D)(B)L*6W1 model can reach -25°C but without capacity
guarantee
2-3 MAIN COMPONENTS
EBHQ011AA6W1
EBHQ014AA6W1
EBHQ016AA6W1
Air heat exchanger
Specifications
Length
mm
857
857
857
Nr of Rows
2
2
2
Fin pitch
mm
1.4
1.4
1.4
Nr of Passes
5
5
5
Face area
m²
1.131
1.131
1.131
Nr of Stages
60
60
60
Tube type
Hi-XSS
Fin
Type
WF fin
Treatment
Anti-corrosion treatment (PE)
Fan
Type
Propeller
Quantity
2
2
2
Discharge direction
Horizontal
Motor
Quantity
2
2
2
Model
Brushless DC
Motor
Speed (nominal)
Steps
8
8
8
Heating
rpm
760
760
760
Cooling
rpm
780
780
780
Fan
Motor
Output
W
70
70
70
Drive
Direct drive
Compressor
Quantity
1
1
1
Motor
Model
JT1G-VDYR@S
Type
Hermetically sealed scroll compressor
Motor Output W
2,200
Starting Method
Inverter driven
Motor
Crankcase Heater
Output
W
33
33
33
Pump
Type
Water cooled
Nr. of speed
2
2
2
Nominal ESP unit
Heating
kPa
52.5
43.5
35.0
Cooling
kPa
55.9
49.1
46.8
Power input
W
210
210
210
Water side Heat
exchanger
Type
Brazed plate
Quantity
1
1
1
Water volume
l
1.01
1.01
1.01
Water flow rate Min.
l/min
16
16
16
Water flow rate
Nom.
Heating
l/min
32.1
40.1
45.9
Cooling
l/min
36.8
45.9
48.0
Water flow rate Max.
l/min
58
58
58
Insulation material
Foamed synthetic elastomer
2-2 TECHNICAL SPECIFICATIONS
EBHQ011AA6W1
EBHQ014AA6W1
EBHQ016AA6W1
Summary of Contents for Altherma EDLQ011-016AA6V3
Page 1: ...technical data EEDEN09 720 Altherma TM ...
Page 3: ...technical data EEDEN09 720 Altherma TM ...
Page 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Page 6: ......
Page 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Page 8: ......
Page 20: ......
Page 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Page 36: ......
Page 52: ......
Page 68: ......
Page 84: ......
Page 176: ......
Page 196: ......
Page 216: ......
Page 236: ......
Page 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Page 238: ......
Page 264: ......
Page 270: ......