background image

 

Operation manual

 

3

 

E(D/B)(H/L)Q011~016BB

 

Unit and options for air to water heat pump system

 

4PW67905-1 – 01.2011

 

4.

O

 

PERATING

 

 

 

THE

 

 

 

UNIT

 

4.1.

Introduction

 

The heat pump system is designed to provide you a comfortable
indoor climate for many years at low energy consumption.

To  get the most comfort with the lowest energy consumption out of
your system, it is very important to observe the items listed below.

Defining possible schedule timer actions for each day and filling out
the form at the very end of this manual can help you minimize the
energy consumption. Ask your installer for support if required.

 

 

Make sure the heat pump system works at the lowest possible
hot water temperature required to heat your house.
To optimize this, make sure the weather dependent set point is
used and configured to match the installation environment.
Refer to 

"5. Field settings" on page 13

.

 

 

It is advised to install the room thermostat connected to the unit.
This will prevent excessive space heating and will stop the unit
and the circulation pump when the room temperature is above
the thermostat set point.

 

 

Next recommendations only apply to installations with an
optional domestic hot water tank.

 

 

Make sure the domestic hot water is only heated up to the
domestic hot water temperature you require.
Start with a low domestic hot water temperature set point
(e.g. 45°C), and only increase if you feel that the domestic
hot water supply temperature is not sufficient.

 

 

Only for tank with built-in electrical booster heater (EKHW*):
Make sure the domestic water heating by booster heater only
start 1 to 2 hours before you expect domestic hot water
usage.
In case you only need a lot of domestic hot water in the
evening or in the morning, only allow domestic water heating
by  booster heater during early morning and early evening.
Also keep hours with low electricity cost tariffs in mind.
To  do this, program both the domestic water heating and
booster heating schedule timer. Refer to 

Programming

  in

chapter 

"4.7. 

Programming and consulting the schedule

timer" on page 9

.

 

 

If the domestic hot water is not used for two weeks or more, a
quantity of hydrogen gas which is highly flammable may
accumulate in the domestic hot water tank. To dissipate this
gas safely, it is recommended that a hot tap be turned on for
several minutes at a sink, basin, or bath, but not at a
dishwasher, clothes washer or other appliance. During this
procedure there must be no smoking, open flame or any
electrical appliance operating nearby. If hydrogen is
discharged through the tap, it will probably make a sound as
of air escaping.

 

4.2.

Operating the digital controller

 

Operating the unit comes down to operating the digital controller.

 

Features and functions

 

The digital controller is a state of the art controller that offers full
control over your installation. It can control a heating/cooling and a
heating only installation.

Both installations are available in multiple versions which vary in
capacity, electrical supply and installed equipment (with an optional
domestic hot water tank).

 

Basic controller functions

 

The basic controller functions are:

 

 

Turning the unit ON/OFF.

 

 

Operation mode change-over:
-

space heating (refer to 

page 6

),

-

space cooling (refer to 

page 6

) (*),

-

domestic water heating (refer to 

page 6

) (*).

 

 

Selection of features:
-

quiet mode (refer to 

page 7

),

-

weather dependent control (refer to 

page 8

).

 

 

Temperature set point adjustment (refer to 

page 7

).

The digital controller supports a power cut off of maximum 2 hours.
When autorestart is enabled (see 

"5. Field settings" on page 13

) this

allows a power supply shut down of 2 hours without user intervention
(e.g. benefit kWh rate power supply).

 

Clock function

 

The clock functions are:

 

 

24 hour real time clock.

 

 

Day of the week indicator.

 

Schedule timer function

 

The schedule timer function allows the user to schedule the
operation of the installation according to a daily or a weekly program.

 

CAUTION

 

Never let the digital controller get wet. This may cause an
electric shock or fire.

Never press the buttons of the digital controller with a hard,
pointed object. This may damage the digital controller.

Never inspect or service the digital controller yourself, ask
a qualified service person to do this.

 

INFORMATION

 

 

Descriptions in this manual that apply to a specific
installation or that depend on the installed equipment,
are marked with an asterisk (*).

 

 

Some functions described in this manual may not be
available or should not be available. Ask your installer
or your local dealer for more information on
permission levels.

 

INFORMATION

 

(*) The functions 'space cooling' and 'domestic water
heating' can only be selected when the corresponding
equipment is installed.

Summary of Contents for Altherma EBHQ-BB6V3

Page 1: ...BB6W1 EDLQ011BB6V3 EDLQ014BB6V3 EDLQ016BB6V3 EDLQ011BB6W1 EDLQ014BB6W1 EDLQ016BB6W1 EBHQ011BB6V3 EBHQ014BB6V3 EBHQ016BB6V3 EBHQ011BB6W1 EBHQ014BB6W1 EBHQ016BB6W1 EBLQ011BB6V3 EBLQ014BB6V3 EBLQ016BB6V3 EBLQ011BB6W1 EBLQ014BB6W1 EBLQ016BB6W1 Unit and options for air to water heat pump system ...

Page 2: ... according to their severity and probability of occurrence Some types of danger are represented by special symbols 1 2 Meaning of used terms Installation manual Instruction manual specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenan...

Page 3: ...out electrical booster heater EKHTS in 2 different sizes 200 and 260 litre Solar kit for domestic hot water tank option For information concerning the EKSOLHW solar kit refer to the installation manual of that kit Room thermostat kit option An optional room thermostat EKRTW EKRTWA or EKRTR can be connected to the unit Refer to the operation manual of the room thermostat for more information 3 2 Sc...

Page 4: ...his gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make a sound as of air escaping 4 2 Operating the digital controller Operat...

Page 5: ...er 11 SET TEMPERATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addressed or a function is not available 14 DEFROST STARTUP MODE ICON d This icon indicates that the defrost startup mode is active 15 COMPRESSOR ICON ç...

Page 6: ...torage set point of the domestic hot water temperature only for 4 03 4 or 5 The buttons are not used when the domestic hot water tank is not installed 34 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set in permission level 2 or 3 refer to 5 Field settings on page 13 the quiet mode button will not be operable 35 BIVALENT FUNCTION OR EXTERNAL BACKUP HEATER ACTI...

Page 7: ...t upon user request 2 Reheat Scheduled The unit will heat up the domestic water tank starting from a scheduled time and untill the reheat set point is reached Preferally this is done during the time of day when space heating demand is lowest Continuous The unit will continuously heat up the domestic water tank untill the reheat set point is reached In this case a balance with the space heating dem...

Page 8: ...e actual temperature set point only appears on the display after pressing one of the buttons wi or wj If no button is pressed for 5 seconds the temperature set point will automatically disappear from the display again Temperature range for domestic water heating For EKHW only 30 C to 78 C For EKHTS only 30 C to 60 C 3 Press the v button to deactivate domestic water heating w Icon w disappears from...

Page 9: ...on with a set point weather dependent or manually set Four actions can be programmed These actions are repeated daily 3 Quiet mode refer to Programming space cooling quiet mode or booster heater mode on page 11 Switch the mode on or off at a scheduled time Four actions can be programmed per mode These actions are repeated daily 4 Domestic water heating refer to Programming space heating or domesti...

Page 10: ...t a requirement but will simplify the interpretation of the program later If 2 or more actions are programmed for the same day and at the same time only the action with the highest action number will be executed You can always alter add or remove the programmed actions later INFORMATION The programmed actions are not stored according to their timing but according to the time of programming This me...

Page 11: ...he programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For domestic water heating use the ba button to enable or disable the x action 10 Use the pi and pj button...

Page 12: ... select For space cooling x switch cooling and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For quiet mode and booster heater mode 1 use the ba button to enable or disable the x action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display sh...

Page 13: ...e button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to copy to the next day by means of the pi and pj buttons The selected day is blinking You can return to st...

Page 14: ...peat step 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface buttons can be made unavailable for the user Three permission levels are defined see the table below Switching between level 1 and level 2 3 is done by simultaneously pressing buttons pfi and pfj i...

Page 15: ...i2_Ti the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature Hi2_A Note that the Hi2_Ti value should be lower than Lo2_Ti as for warmer outdoor temperatures i e Hi2_A colder water is required Tt Target water temperature TA Ambient outdoor temperature Shift value Shift value 2 Disinfection function Applies only to installations with a d...

Page 16: ... hysteresis Example 1 Scheduled storage 6 03 1 scheduled reheat 6 05 1 disinfection function 2 01 1 activated A Scheduled storage operation activated at 6 04 heat up domestic hot water untill domestic hot water user interface set point TDHW e g 55 C is reached B Scheduled reheat operation activated at 6 06 heat up domestic hot water untill domestic hot water reheat set point 6 07 e g 45 C is reach...

Page 17: ...ing automatic storage during night default setting If it seems that the domestic hot water night storage operation is not sufficient for your needs an additional scheduled reheat during daytime can be set NOTICE The setting 4 03 shall not be modified The installer selected the proper setting for your application INFORMATION The status of this setting is only mentioned to indicate which settings an...

Page 18: ...r to the installation manual of that kit d Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent set point see field setting 1 Weather dependent set point on page 14 is selected d 03 Local shift value weather dependent determines the shift value of the weather dependent set point arou...

Page 19: ...Fri Mon Sun All 01 Status 1 ON 0 1 02 Start time 23 00 0 00 23 00 1 00 hour 03 Set point only in combination with domestic hot water tank without electrical booster heater EKHTS 60 fixed 5 C 03 Set point only in combination with domestic hot water tank with built in electrical booster heater EKHW 70 55 80 5 C 04 Interval only in combination with domestic hot water tank without electrical booster h...

Page 20: ...stallation related setting 9 Heating and cooling set point ranges 00 Heating set point upper limit 55 37 55 1 C 01 Heating set point lower limit 25 15 37 1 C 02 Cooling set point upper limit 22 18 22 1 C 03 Cooling set point lower limit 5 5 18 1 C 04 Installation related setting Automatic set back function 05 Set back operation 0 OFF 0 1 1 06 Set back operation start time 23 00 0 00 23 00 1 00 hou...

Page 21: ... Not applicable Do not change the default value E Unit information readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Do not change the default value depending on model 03 Liquid refrigerant temperature Read only 1 C 04 Inlet water temperature Read only 1 C F Installation related setting 00 Installation related setting 01 Installation related setting 02 ...

Page 22: ...void injury give the piping time to return to normal temperature or be sure to wear proper gloves Do not touch any switch with wet fingers Touching a switch with wet fingers can cause electrical shock WARNING Do not touch the refrigerant pipes during and immediately after operation as the refrigerant pipes may be hot or cold depending on the condition of the refrigerant flowing through the refrige...

Page 23: ... shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with the applicable legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correct...

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4PW67905 1 01 2011 Copyright 2011 Daikin ...

Reviews: