4 Installation
Installation manual
6
EABH/X16DA+9W
Daikin Altherma – Low temperature split
4P556066-1 – 2018.10
4×
3
If you have to do work behind the switch box, open the switch
box.
2×
1
2
4
If you have to do work behind the user interface panel or upload
new software into the user interface, open the user interface
panel.
1
2
3
2×
5
Optional: Remove the user interface panel.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the panel to prevent damage.
3
1
2
4.2
Mounting the indoor unit
4.2.1
To install the indoor unit
1
Fix the wall bracket (accessory) to the wall (level) with 2 Ø8 mm
bolts.
2×
a
a
Optional: If you want to fix the unit to the wall from inside
the unit, provide an additional screw plug.
2
Lift the unit.
42 kg
3
Attach the unit to the wall bracket:
▪ Tilt the top of the unit against the wall at the position of the
wall bracket.
▪ Slide the bracket on the back of the unit over the wall
bracket. Make sure the unit is fixed properly.