10
|
Configuration
Installer reference guide
163
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
(a)
158].
10.6 Settings menu
You can set additional settings using the main menu screen and its submenus. The
most important settings are presented here.
10.6.1 Malfunctioning
In case of a malfunction, or
will appear on the home screen. To display the
error code, open the menu screen and go to [0]
Malfunctioning
. Press for
more information about the error.
0
Malfunctioning
Room
Operation
User profile
Main zone
10.6.2 Room
Overview
The following items are listed in the submenu:
1
Room
Main zone
Malfunctioning
Operation
Additional zone
[1]
Room
Setpoint screen
[1.1]
Schedule
[1.2]
Heating schedule
[1.3]
Cooling schedule
[1.4]
Antifrost
[1.5]
Setpoint range
[1.6]
Room sensor offset
[1.7]
Room sensor offset
[1.9]
Room comfort setpoint
Setpoint screen
Control the room temperature of the main zone via setpoint screen [1]
Room
.
See
146].
Schedule
Indicate if the room temperature is controlled according to a schedule or not.
#
Code
Description
[1.1]
N/A
Schedule
:
▪
No
: Room temperature is directly controlled by
the user.
▪
Yes
: Room temperature is controlled by a
schedule and can be modified by the user.