3 Operation

Operation manual

6

EHFZ03S18DJ3V

Daikin Altherma 3 R F

4P596819-1 – 2019.10

3.3

Space heating control

NOTICE

Room frost protection.

 Even if you turn OFF the leaving

water temperature (main + additional) control via the home
pages  (

LWT  main

  + 

LWT  add

),  room  frost  protection  –if

enabled– will remain active.

NOTICE

Water  pipe  freeze  prevention.

  Even  if  you  turn  OFF  the

leaving  water  temperature  (main  +  additional)  control  via
the home pages (

LWT main

 + 

LWT add

), water pipe freeze

prevention –if enabled– will remain active.

3.3.1

Setting the space operation mode

About space operation modes

The heat pump is a heating only model. The system can heat up a
space, but NOT cool down a space.

3.3.2

Room thermostat control - Using the
room temperature home pages

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  To  set  the  user  profile,  refer  to
Configuring  user  profile  and  home  pages  in  the  user  reference
guide.

User profile = 

Basic

User profile = 

Detailed

15:20

20.0°C

Mon

Room

Actual temperature

15:20

20.0°C

17:30

Actual temperature

Room

Scheduled

Mon

Tue

To read out the actual and desired room
temperature

1

Go to the room temperature home page (

Room

).

Result: 

You  can  read  out  the  actual  temperature.

20.0°C

Actual temperature

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature.

22.0°C

Desired temperature

To temporarily overrule the room temperature
schedule

1

Go to the room temperature home page (

Room

).

2

In the detailed home page (user profile = 

Detailed

), select the

scheduled  room  temperature  mode  (

)  by  pressing 

  or

.

Result: 

The room temperature follows the scheduled value.

3

Use 

 or 

 to adjust the temperature.

Result: 

The  room  temperature  follows  the  manually  adjusted

value  ( ),  but  will  return  to  the  scheduled  value  at  the  next
scheduled action.

To change the mode from scheduled to preset
value

Prerequisite: 

User profile = 

Detailed

.

1

Go to the room temperature home page (

Room

).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The  room  temperature  follows  the  preset  value

(

Comfort

 or 

Eco

), but will return to the scheduled value after the

overrule  period  (= 

Temperature  lock

:  2/4/6/8  hours  or

permanent).

3

If necessary, you can overrule the preset value by using 

 or

 to adjust the temperature.

Result: 

The  room  temperature  follows  the  manually  adjusted

value  ( ),  but  will  return  to  the  scheduled  value  after  the
overrule  period  (= 

Temperature  lock

:  2/4/6/8  hours  or

permanent).

To set the overrule period

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [7.2]: 

 > 

User settings

 > 

Temperature lock

.

2

Select a value and press 

:

Permanent

hours

 (2, 4, 6, 8)

3.3.3

Room thermostat control - Using the
leaving water temperature home pages

For  more  information  about  the  leaving  water  temperature,  see  the
user reference guide.

3.4

Domestic hot water control

NOTICE

Disinfection  mode

.  Even  if  you  turn  OFF  domestic  hot

water operation via the DHW tank temperature home page
(

Tank

), disinfection mode will remain active.

3.4.1

Reheat mode

In  reheat  mode  ( ),the  DHW  tank  continuously  heats  up  to  the
temperature  shown  on  the  DHW  tank  temperature  home  page
(example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

Tt

T

t

Domestic hot water tank temperature

t

Time

INFORMATION

There  is  a  risk  of  a  space  heating  capacity  shortage/
comfort problem when selecting [6‑0D]=0 ([A.4.1] Domestic
hot water 

Type

=

Reheat only

).

In case of frequent domestic hot water operation, frequent
and long space heating interruption will happen.

3.4.2

Scheduled mode

In  scheduled  mode  ( ),  the  DHW  tank  produces  hot  water
corresponding  to  a  schedule.  The  best  time  to  allow  the  tank  to
produce hot water is at night, because the space heating demand is
lower.

Example: 

Summary of Contents for Altherma 3 R F

Page 1: ...Operation manual Daikin Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHFZ03S18DJ3V...

Page 2: ...4 Symptom Heat pump failure 9 6 5 Symptom The system is making gurgling noises after commissioning 9 7 Disposal 9 8 Glossary 10 1 Installer settings Tables to be filled in by installer 1 1 Quick wizar...

Page 3: ...n of the installation good practices reference data Format Digital files on http www daikineurope com support and manuals product information Addendum book for optional equipment Additional info about...

Page 4: ...rature home page Desired room temperature according to the selected schedule On the DHW tank temperature home page DHW tank mode Scheduled mode DHW tank mode Reheat mode DHW tank mode Scheduled reheat...

Page 5: ...unning hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempera...

Page 6: ...lue but will return to the scheduled value at the next scheduled action To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room...

Page 7: ...ther dependent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Pr...

Page 8: ...water pump only during periods of the day when instant hot water is necessary Example In the morning and evening 5 Maintenance and service 5 1 Overview Maintenance and service The installer has to per...

Page 9: ...eater can serve as an emergency heater and either automatically or non automatically take over the heat load When auto emergency is activated and a heat pump failure occurs the backup heater will auto...

Page 10: ...FZ03S18DJ3V Daikin Altherma 3 R F 4P596819 1 2019 10 8 Glossary DHW Domestic hot water Hot water used in any type of building for domestic purposes LWT Leaving water temperature Water temperature at t...

Page 11: ......

Page 12: ...4P596819 1 2019 10 Copyright 2019 Daikin 4P383117 1 D 0000000 4P596819 1 0000000 Verantwortung f r Energie und Umwelt...

Reviews: