Daikin Altherma 3 R F Operation Manual Download Page 3

2 General information

Operation manual

3

EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596819-1 – 2019.10

2

General information

2.1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Installation manual – Outdoor unit:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installation manual – Indoor unit:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation  of  the  installation,  good  practices,  reference

data, …

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format:  Paper  (in  the  box  of  the  unit)  +  Digital  files  on 

http://

www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

Breadcrumbs

1

20.0°C >
18.0°C >

7.4.1.1

Room temperature

Comfort (heating)
Eco (heating)

Select

Scroll

Breadcrumbs help you to locate where you are in the menu structure
of  the  user  interface.  This  document  also  mentions  these
breadcrumbs.

Example: 

Go to [7.4.1.1]: 

 > 

User settings

 > 

Preset values

 >

Room temperature

 > 

Comfort (heating)

2.2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Produce domestic hot water

2.2.1

Components in a typical system layout

g

A

d

b

a

f

e

c

B

C

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface of the indoor unit

e

User interface used as room thermostat

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

3

Operation

3.1

User interface: Overview

3.1.1

Buttons

Overview

a

e

f

b

d

c

a

Home pages

b

Malfunction information

c

On/Off

Summary of Contents for Altherma 3 R F

Page 1: ...Operation manual Daikin Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHFZ03S18DJ3V...

Page 2: ...4 Symptom Heat pump failure 9 6 5 Symptom The system is making gurgling noises after commissioning 9 7 Disposal 9 8 Glossary 10 1 Installer settings Tables to be filled in by installer 1 1 Quick wizar...

Page 3: ...n of the installation good practices reference data Format Digital files on http www daikineurope com support and manuals product information Addendum book for optional equipment Additional info about...

Page 4: ...rature home page Desired room temperature according to the selected schedule On the DHW tank temperature home page DHW tank mode Scheduled mode DHW tank mode Reheat mode DHW tank mode Scheduled reheat...

Page 5: ...unning hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempera...

Page 6: ...lue but will return to the scheduled value at the next scheduled action To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room...

Page 7: ...ther dependent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Pr...

Page 8: ...water pump only during periods of the day when instant hot water is necessary Example In the morning and evening 5 Maintenance and service 5 1 Overview Maintenance and service The installer has to per...

Page 9: ...eater can serve as an emergency heater and either automatically or non automatically take over the heat load When auto emergency is activated and a heat pump failure occurs the backup heater will auto...

Page 10: ...FZ03S18DJ3V Daikin Altherma 3 R F 4P596819 1 2019 10 8 Glossary DHW Domestic hot water Hot water used in any type of building for domestic purposes LWT Leaving water temperature Water temperature at t...

Page 11: ......

Page 12: ...4P596819 1 2019 10 Copyright 2019 Daikin 4P383117 1 D 0000000 4P596819 1 0000000 Verantwortung f r Energie und Umwelt...

Reviews: