Unit installation
Installer reference guide
86
ERLA11~W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09
7.4 Mounting the indoor unit
7.4.1 About mounting the indoor unit
When
You have to mount the outdoor and indoor unit before you can connect the
refrigerant and water piping.
Typical workflow
Mounting the indoor unit typically consists of the following stages:
1
Installing the indoor unit.
2
Connecting the drain hose to the drain.
7.4.2 Precautions when mounting the indoor unit
INFORMATION
Also read the precautions and requirements in the following chapters:
▪
"2 General safety precautions"
▪
"7.1 Preparing the installation site"
7.4.3 To install the indoor unit
1
Lift the indoor unit from the pallet and place it on the floor. Also see
26].
2
Connect the drain hose to the drain. See
"7.4.4 To connect the drain hose to
3
Slide the indoor unit into position.
4
Adjust the height of the leveling feet to compensate for floor irregularities.
The maximum allowed deviation is 1°.
≤1°
NOTICE
Do NOT tilt the unit forwards:
0°
1° 1°