4
|
Operation
User reference guide
18
EHBH/X04+08DA*V7 + EHVH/X04+08S(U)18+23DA/DJ3V+6V+9W7
Daikin Altherma 3 R F+W
4P618959-1 – 2020.03
1
Go to [C.2]:
Operation
>
Space heating/cooling
.
Operation
Space heating/cooling
Tank
Off
On
On
Room
C.2
2
Set operation to
On
or
Off
.
Tank heating operation
NOTICE
Disinfection mode
. Even if you turn OFF tank heating operation ([C.3]:
Operation
>
Tank
), disinfection mode will remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1
Go to [C.3]:
Operation
>
Tank
.
Operation
Tank
Off
On
Space heating/cooling
C.3
2
Set operation to
On
or
Off
.
4.4 Space heating/cooling control
4.4.1 About space heating/cooling control
Controlling space heating/cooling typically consists of the following stages:
1
Setting the space operation mode
2
Controlling the temperature
Depending on the system layout and installer configuration, you use a different
temperature control:
▪
Room thermostat control
▪
Leaving water temperature control
▪
External room thermostat control
4.4.2 Setting the space operation mode
About space operation modes
Your unit can be a heating or a heating/cooling model:
▪
If your unit is a heating model, it can heat up a space.
▪
If your unit is a heating/cooling model, it can both heat up and cool down a
space. You have to tell the system which operation mode to use.
To determine if a heating/cooling heat pump model is installed
1
Go to [4]:
Space heating/cooling
.
2
Check if [4.1]
Operation mode
is listed and editable. If so, a
heating/cooling heat pump model is installed.