background image

User reference guide 

Daikin Altherma 3 R F+W

EBBH11D

6V

EBBH11D

9W

EBBH16D

6V

EBBH16D

9W

EBBX11D

6V

EBBX11D

9W

EBBX16D

6V

EBBX16D

9W

EB23D

6V

EB23D

9W

EB23D

6V

EB23D

9W

EBVH16SU23D

6V

EB23D

6V

EB23D

9W

EB23D

6V

EB23D

9W

= A, B, C, …, Z

= , , 1, 2, 3, …, 9

Summary of Contents for Altherma 3 R F+W EBBH11D 6V Series

Page 1: ...1D 6V EBBH11D 9W EBBH16D 6V EBBH16D 9W EBBX11D 6V EBBX11D 9W EBBX16D 6V EBBX16D 9W EBVH11S18 23D 6V EBVH11S18 23D 9W EBVH16S18 23D 6V EBVH16S18 23D 9W EBVH16SU23D 6V EBVX11S18 23D 6V EBVX11S18 23D 9W...

Page 2: ...5 6 4 To change the desired room temperature 29 5 6 5 To change the desired leaving water temperature 30 5 7 Domestic hot water control 31 5 7 1 About domestic hot water control 31 5 7 2 Reheat mode 3...

Page 3: ...rma 3 R F W 4P643607 1B 2022 08 8 6 Symptom The system is making gurgling noises after commissioning 60 9 Relocation 62 9 1 Overview Relocation 62 10 Disposal 63 11 Glossary 64 12 Installer settings T...

Page 4: ...n the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on https www daikin eu Use the search...

Page 5: ...help button The breadcrumbs appear in the top left corner of the screen 2 To disable the breadcrumbs Press the help button again This document also mentions these breadcrumbs Example 1 Go to 4 3 Spac...

Page 6: ...es a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the in...

Page 7: ...educed physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the h...

Page 8: ...NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible...

Page 9: ...entilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Air...

Page 10: ...he main zone can only provide refreshment Real cooling is then NOT allowed 3 1 Components in a typical system layout g A d b a f e c B C A Main zone Example Living room B Additional zone Example Bedro...

Page 11: ...se through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code...

Page 12: ...temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperature 1 Go to 1 Room Room 1 2 Adjust the desired room temperature 21 C 1 a b Room a...

Page 13: ...curve Additional zone Cooling 3 6 Additional zone Cooling WD curve 2 Change the weather dependent curve There are 2 types of WD curves slope offset curve default and 2 points curve If needed you can...

Page 14: ...d set offset Confirm changes and return to the submenu 2 points curve Y1 Y2 X1 X2 X1 X2 Outdoor ambient temperature Y1 Y2 Desired leaving water temperature Possible actions on this screen Go through t...

Page 15: ...perature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjust the domestic hot water temperature 50 C 5 a b Tank a Actual domestic hot water tempera...

Page 16: ...e User reference guide 16 EBBH X11 16D EBVH X11 16S U 18 23D Daikin Altherma 3 R F W 4P643607 1B 2022 08 5 4 Turning operation ON or OFF 425 5 7 Domestic hot water control 431 5 8 Preset values and sc...

Page 17: ...ator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Ma...

Page 18: ...onfirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help button Press to show a help text related to t...

Page 19: ...etpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4...

Page 20: ...Screen with weather dependent curve c4 Screen with schedule 5 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint tem...

Page 21: ...or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currently being used for space heating e3 Smart energy...

Page 22: ...e Underfloor heating Fancoil unit Radiator i3 21 Measured room temperature a i4 35 Leaving water temperature setpoint a j Holiday mode Holiday mode active k Additional zone k1 Installed room thermosta...

Page 23: ...Human Comfort Interface BRC1HHDA used as room thermostat is controlling the indoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving...

Page 24: ...onfiguring the ONECTA app 5 3 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature screen 21 C 1 Room 2 Ma...

Page 25: ...ours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and proceed...

Page 26: ...activate However for leaving water temperature control and external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating coolin...

Page 27: ...and WLAN 8 9 Running hours Running hours of specific system components 5 6 Space heating cooling control 5 6 1 About space heating cooling control Controlling space heating cooling typically consists...

Page 28: ...he status indicator will show a blue pulsation with an interval of approximately 5 seconds While the unit is in operation the status indicator will light up blue constantly To set the space operation...

Page 29: ...ture control you are using 6 1 6 bar 22 19 55 21 35 45 a2 a1 b 18 Feb 2018 a1 Heat emitter of the main zone in this example Underfloor heating a2 Heat emitter of the additional zone in this example Ra...

Page 30: ...occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 5 6 5 To change the desired leaving water t...

Page 31: ...one of the following 2 1 Main zone Schedule 3 1 Additional zone Schedule 2 Select No To enable weather dependent operation for the leaving water temperature See 5 9 4 Using weather dependent curves 44...

Page 32: ...or the tank the tank temperature is determined automatically by the outdoor temperature For more information see 5 9 Weather dependent curve 445 To determine which domestic hot water mode you are usin...

Page 33: ...tions it is recommended to switch to one of the following modes Schedule only Schedule reheat 5 7 3 Scheduled mode In scheduled mode the DHW tank produces hot water corresponding to a schedule The bes...

Page 34: ...1 2 4 5 3 Tt Domestic hot water tank temperature t Time 5 7 5 To change the domestic hot water temperature In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust t...

Page 35: ...e water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating cooling and capacity shortage comfort problems is significant In case of frequent domestic ho...

Page 36: ...ur system layout and installer configuration schedules for multiple controls may be available You can See Set if a specific control needs to act according to a schedule Activation screen in Possible s...

Page 37: ...ions Actions you can use when programming a schedule For most schedules you can program up to 6 actions per day Schedule Control Description 1 2 Room Heating schedule Schedule for the desired room tem...

Page 38: ...zone On When the system is allowed to cool down the additional zone 4 2 Space heating cooling Operation mode schedule Schedule per month for when to operate the unit in heating mode and when in coolin...

Page 39: ...values High Medium Low See 5 8 4 Setting the energy prices 443 Restriction Only available to installers 9 4 2 Installer settings Booster heater BSH allowance schedule Predefined schedules 1 Activatio...

Page 40: ...unday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name o...

Page 41: ...colour than a low temperature 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon Note To clear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule fo...

Page 42: ...un User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit...

Page 43: ...characters 5 Confirm the new name INFORMATION Not all schedules can be renamed Usage example You work in a 3 shift system If you work in a 3 shift system you can do the following 1 Program 3 room tem...

Page 44: ...electricity supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the electricity price for Hi...

Page 45: ...operates weather dependent if the desired leaving water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on the North wall o...

Page 46: ...ee 5 9 4 Using weather dependent curves 448 Availability The weather dependent curve is available for Main zone Heating Main zone Cooling Additional zone Heating Additional zone Cooling Tank only avai...

Page 47: ...nd offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water for different ambient temperatures For ex...

Page 48: ...one heating Main zone or additional zone cooling Domestic hot water X1 X2 Examples of outdoor ambient temperature Y1 Y2 Y3 Y4 Examples of desired tank temperature or leaving water temperature The icon...

Page 49: ...ge the type for all zones main additional and for the tank go to 2 E Main zone WD curve type Viewing which type is selected is also possible via 3 C Additional zone WD curve type 5 E Tank WD curve typ...

Page 50: ...oor temperatures Slope Offset OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot To fine tune the weather dependent curve 2 points curve The following table describes how to fine tune t...

Page 51: ...ive To program a quiet mode schedule Restriction Only possible if enabled by the installer 1 Go to 7 4 2 User settings Quiet Schedule 2 Program the schedule Possible actions You can use the following...

Page 52: ...es 3 Set the last day of your holiday Go to 7 3 3 Till Select a date Confirm the changes 5 10 4 Using WLAN INFORMATION Restriction WLAN settings are only visible when a WLAN cartridge or WLAN module i...

Page 53: ...ile doing this the following actions and information are needed on the user interface D Wireless gateway Malfunctioning Operation User profile Room D Wireless gateway D 1 Mode D 2 Reboot D 3 WPS D 4 R...

Page 54: ...cloud 2 In the Remove from cloud screen select Yes D 5 Home network connection Read out the status of the connection to the home network 1 Go to D 5 Wireless gateway Home network connection 2 Read ou...

Page 55: ...when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in low...

Page 56: ...ur installer for more information WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The refrigerant inside the unit is mildly flammable but normally does N...

Page 57: ...8 NOTICE Applicable legislation on fluorinated greenhouse gases requires that the refrigerant charge of the unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2...

Page 58: ...case of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the lef...

Page 59: ...heat emitter type See 5 6 5 To change the desired leaving water temperature 430 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 5 9 Weather dependent curve 445 8...

Page 60: ...cy is set to auto SH reduced DHW on space heating is reduced but domestic hot water is still available auto SH reduced DHW off space heating is reduced and domestic hot water is NOT available auto SH...

Page 61: ...ith the air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before...

Page 62: ...18 23D Daikin Altherma 3 R F W 4P643607 1B 2022 08 9 Relocation 9 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact helpdesk number vi...

Page 63: ...W 4P643607 1B 2022 08 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Page 64: ...r domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application exp...

Page 65: ...ckup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Booster heater capacity 9 4 1 if applicable Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1...

Page 66: ...erma 3 R F W 4P643607 1B 2022 08 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 12 2 Settings menu Setting Fil...

Page 67: ......

Page 68: ...4P643607 1B 2022 08 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: