11
|
Configuration
Installer reference guide
214
ERLA11~W1 + EBSH/X(B)11+16P30+50DF
Daikin Altherma 3 R ECH₂O
4P663482-1A – 2021.11
Calculation of the electricity price
Electricity price=Actual electricity price+Incentive/kWh
Electricity price=12.49+5
Electricity price=17.49
Price
Value in breadcrumb
Gas: 4.08 /kWh
[7.6]=8.6
Electricity: 12.49 /kWh
[7.5.1]=17
11.5.8 Information
Overview
The following items are listed in the submenu:
8
Information
Installer settings
User settings
Tank
Commissioning
[8]
Information
[8.1]
Energy data
[8.2]
Malfunction history
[8.3]
Dealer information
[8.4]
Sensors
[8.5]
Actuators
[8.6]
Operation modes
[8.7]
About
[8.8]
Connection status
[8.9]
Running hours
[8.A]
Reset
[8.B]
Piping diagram
Energy data
Read out information about energy flows to check and optimize your energy
consumption. You can read out electricity input and produced heat divided into
space heating, space cooling and storage tank heating. Additionally the storage
tank heat (provided e.g. by a solar system) used for space heating can be read out
(
Produced heat
>
Tank
). This heat is NOT included in the sum of the produced
heat.
The energy flow screen (
Energy data
>
Energy flow
) visualizes the various
energy flows. A highlighted arrow shows a current energy flow, e.g. from the tank
to the space heating circuit.
Dealer information
The installer can fill in his contact number here.
#
Code
Description
[8.3]
N/A
Number that users can call in case of problems.
Reset
Reset the configuration settings stored in the MMI (user interface of the indoor
unit).
Example:
Energy meterings, holiday settings.
Summary of Contents for Altherma 3 R ECH2O
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ...4P663482 1A 2021 11 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...