5
|
About the units and options
Installer reference guide
28
EPRA08~W1 + ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663478-1 – 2021.07
5.2.2 Identification label: Indoor unit
Location
Model identification
Example:
E TS H B 12 P 50 EF
Code
Description
E
European model
TS
Floor-standing hydro-split unit with integrated pressureless
storage tank
H
H=Heating only
X=Heating/cooling
B
Integrated heat exchanger for bivalent heat generator
12
Capacity class
P
Integrated tank material: Plastics
50
Integrated tank volume
EF
Model series
5.3 Combining units and options
INFORMATION
Certain options may NOT be available in your country.
5.3.1 Possible combinations of indoor unit and outdoor unit
Indoor unit
Outdoor unit
EPRA08
EPRA10
EPRA12
ETSH/X
O
O
O
Summary of Contents for Altherma 3 H MT ECH2O