Configuration
Installer reference guide
127
EPGA11~ EAV23DA6V
Daikin Altherma 3 H F
4P606487-1 – 2019.12
INFORMATION
The setting [F‑0B] is only valid when there is a thermostat or external room
thermostat request setting (NOT in case of leaving water temperature setting).
8.4.4 Additional zone
Setpoint screen
Control the leaving water temperature for the additional zone via setpoint screen
[3]
Additional zone
.
See
Schedule
Indicates if the desired leaving water temperature is according to a schedule.
See
#
Code
Description
[3.1]
N/A
Schedule
:
▪
No
▪
Yes
Heating schedule
Define a heating temperature schedule for the additional zone via [3.2]
Heating
schedule
.
See
"8.3.8 Schedule screen: Example"
110].
Cooling schedule
Define a cooling temperature schedule for the additional zone via [3.3]
Cooling
schedule
.
See
"8.3.8 Schedule screen: Example"
110].
Setpoint mode
The setpoint mode of the additional zone can be independently set from the
setpoint mode of the main zone.
See
#
Code
Description
[3.4]
N/A
Setpoint mode
:
▪
Fixed
▪
WD heating, fixed cooling
▪
Weather dependent
Heating WD curve
Set weather-dependent heating for the additional zone (if [3.4]=1 or 2):