3
Mode of Operation
The thermostat is a programmable, manual or auto changeover, up to 3-stage heat (depending on your model) and up to
3-stage cool (depending on your model) thermostat. It functions with air conditioning, heat pumps, gas, oil, or electric heat
systems. The thermostat activates the heating appliance when the room temperature is below the set heat temperature (by the
differential temperature). When the call for heat has been satisfied, the outputs are turned off. With heat pumps, the thermostat
will not let the compressor come on for 4 minutes after it turns off to protect your compressor.
When the room temperature is greater than the set cool temperature (by the differential temperature), the cooling device is
activated. When the call for cooling has been satisfied, the outputs are turned off. The thermostat will not let the compressor
come on for 4 minutes after it turns off to protect your compressor.
The program schedule can be overridden by changing the set temperature (
or
). This puts the thermostat into a
temporary hold. To remove the temporary hold, press
icon twice.
Once connected to your wireless network; the thermostat can be monitored and controlled using the “Daikin I3 Thermostat app”
(available for most devices).