19
CONFIG
HUMIDITY
20.
Condition to Turn On
Set the condition for system to follow:
Humidification
No
= No condition other than humidity reading below setpoint and differential will turn on the
humidifier.
HEAT
= Heat must be energized in order for the humidifier to turn on.
HEAT-FAN
: Either the heat or the fan must be energized in order for the humidifier to turn on.
Dehumidification
No
= No condition other than humidity reading above setpoint and differential will turn on the dehumidifier.
COOL-FAN
= Either the cooling system or the fan must be energized in order for the dehumidifier to turn on.
COOL-no
= Cooling system cannot be energized in order for the dehumidifier to turn on.
Press
or
to select.
Press
to advance to the next screen.
CONFIG
HUMIDITY
%RH
19.
Humidity Differential
(1% to 10%)
Set the percent difference between the setpoint humidity and when the humidifier or dehumidifier
system turns on.
Press
or
to select.
Press
to advance to the next screen.
CONFIG
HUMIDITY
18.
Humidification/Dehumidification
(Hu, dE)
Set system configuration to work with a humidifier or dehumidifier (including air conditioner).
Note:
Incorrect settings can damage system and/or cause potentially dangerous conditions.
Use the code described in Configuration Safety Lock to access this screen setting.
Hu
: used with a humidifier to humidify home.
dE
: used with air conditioner or dehumidifier to dehumidify home.
Press
or
to select.
Press
to advance to the next screen.
Note:
Humidity option is only available on 910193134 model only.