background image

INSTALLATION 
MANUAL

R410A Split Series

Models 
3MXS40K2V1B

2AMX52E2V1B

3MXS40K3V1B

2AMX52E3V1B

2MXS52E2V1B

3MKS50E2V1B

2MXS52E3V1B

3MKS50E3V1B

3MXS52E2V1B

4MKS58E2V1B

3MXS52E3V1B

4MKS58E3V1B

3MXS52E4V1B
3AMX52E2V1B
3AMX52E3V1B
3AMX52E4V1B

Deutsch

Français

Nederlands

Español

Italiano

Ελληνικ

Ü

Portugues

Р

ó

сс

ê

ий

English

Türkçe

Installation manual

R410A Split series

Montaj kýlavuzlarý

     R410A Split serisi

Installationsanleitung

Split-Baureihe R410A

Manuel d’installation

Série split R410A

Montagehandleiding

R410A Split-systeem

Manual de instalación

Serie Split R410A

Manuale d’installazione

Serie Multiambienti R410A

Εγχειρ

ß

διο

 

εγκατ

Ü

σταση

ò

διαιρο

ýì

ενη

ò 

σειρ

Üò R410A

Manual de Instalação

     Série split R410A

Р

óê

оводство

 

по

 

монтаж

ó

Серия

 R410A 

с

 

раздельной

 ó

станов

ê

ой

00_CV_3P164392-4P.fm  Page 1  Tuesday, October 30, 2012  11:06 AM

Summary of Contents for 2AMX52E2V1B

Page 1: ...nglish Türkçe Installation manual R410A Split series Montaj kýlavuzlarý R410A Split serisi Installationsanleitung Split Baureihe R410A Manuel d installation Série split R410A Montagehandleiding R410A Split systeem Manual de instalación Serie Split R410A Manuale d installazione Serie Multiambienti R410A Εγχειρßδιο εγκατÜστασηò διαιροýìενηò σειρÜò R410A Manual de Instalação Série split R410A Рóêовод...

Page 2: ...STRIES LTD Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC 3SB64564 17J 3MXS40K2V1B Shinri Sada Manager Quality Control Department DAIKIN TCF 015 N20 09 2011 DEKRA Certification B V NB0344 74736 KRQ EMC97 4957 3SB64564 17J fm Page 1 Thursday October 27 2011 3 50 PM ...

Page 3: ... 2004 108 EC 3SB64564 1 Shinri Sada Manager Quality Control Department 1st of Dec 2008 DAIKIN TCF 015 K1 07 2007 2MXS52E2V1B 2AMX52E2V1B 3MXS52E2V1B 3AMX52E2V1B 3MKS50E2V1B 4MKS58E2V1B 2MXS52E3V1B 2AMX52E3V1B 3MXS52E3V1B 3AMX52E3V1B 3MKS50E3V1B 4MKS58E3V1B KEMA Quality B V 74736 KRQ EMC97 4957 3SB64564 1 fm Page 1 Friday March 13 2009 8 18 PM ...

Page 4: ... 3MXS40K2V1B 2MXS52E2V1B 2AMX52E2V1B 3MXS52E2V1B 3AMX52E2V1B 3MKS50E2V1B 4MKS58E2V1B 2MXS52E3V1B 2AMX52E3V1B 3MXS52E3V1B 3AMX52E3V1B 3MKS50E3V1B 4MKS58E3V1B 3SB65451 5A Shinri Sada Manager Quality Control Department 3SB65451 5A fm Page 1 Thursday October 27 2011 4 52 PM ...

Page 5: ...N TCF 015 P6 07 2012 DEKRA Certification B V NB0344 74736 KRQ EMC97 4957 3SB65451 9D Shinri Sada Manager Quality Control Department 3MXS40K3V1B 3MXS52E4V1B 3AMX52E4V1B Machinery 2006 42 EC Electromagnetic Compatibility 2004 108 EC Low Voltage 2006 95 EC 3SB65451 9D fm Page 1 Wednesday September 19 2012 9 43 AM ...

Page 6: ...3SB65451 4 fm Page 2 Thursday October 27 2011 4 49 PM ...

Page 7: ...als If refrigerant gas leaks during installation ventilate the area immediately Toxic gas may be produced if the refrigerant comes into contact with fire After completing installation check for refrigerant gas leakage Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire such as a fan heater stove or cooker When installing or relocating t...

Page 8: ...rrosion may shorten the life of the air condi tioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which must be kept away from moisture NOTE Cannot be installed hanging from ceiling or stacked CAUTION When operating the air conditioner in a low outdoor ambient temper ature be sure to follow the instructions described below To prevent exposure to wind install the...

Page 9: ...ion pipe s cut line Wrap the insulation pipe with the finishing tape from bottom to top Caulk pipe hole gap with putty Foot bolt hole centres 580 Foot bolt hole centres 330 250mm from wall Allow space for piping and electrical servicing Allow 300mm of work space below the ceiling surface If there is the danger of the unit falling or overturning fix the unit with foundation bolts or with wire or ot...

Page 10: ...rength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts Prepare 4 sets of M8 or M10 foundation bolts nuts and washers each which are available on the market It is best to screw in the foundation bolts until their ends are 20mm from...

Page 11: ...room is 3m Outdoor unit capacity class 2MXS52 2AMX52 3MXS40 3MXS52 3AMX52 3MKS50 4MKS58 Piping to each indoor unit 25m max Total length of piping between all units 50m max If the outdoor unit is positioned higher than the indoor units If the outdoor unit is positioned otherwise If lower than one or more indoor units Wall facing one side Side view More than 100 Direction of air More than 350 1200 o...

Page 12: ...n oil for R410A Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand Then tighten them fully with the torque wrenches Drain water hole Bottom frame Drain plug While pressing Hose available commercially inner dia 16mm Flare nut tightening torque Flare nut for φ6 4 14 2 ...

Page 13: ...valve Hi High pressure valve subsequently requires no operation 3 Apply vacuum pumping Check that the compound pressure gauge reads 0 1MPa 76cmHg Evacuation for at least 1 hour is recommended 4 Close gauge manifold s low pressure valve Lo and stop vacuum pump Leave as is for 4 5 minutes and make sure the coupling meter needle does not go back If it does go back this may indicate the presence of mo...

Page 14: ...ant may slowly leak out do not leave the flare nut removed for a long period of time Outdoor capacity class 2MXS52 2AMX52 3MXS40 3MXS52 3AMX52 Total length of piping for all rooms 30m Filling a cylinder with an attached siphon Stand the cylinder upright when filling There is a siphon pipe inside so the cylinder need not be upside down to fill with liquid Filling other cylinders Turn the cylinder u...

Page 15: ... units Never use piping which has been used for previous installations Only use parts which are delivered with the unit Do never install a drier to this R410A unit in order to guarantee its lifetime The drying material may dissolve and damage the system Incomplete flaring may cause refrigerant gas leakage Gas pipe O D 9 5mm 12 7mm Thickness 0 8mm C1220T O O D 15 9mm Thickness 1 0mm C1220T O Liquid...

Page 16: ...r unit where the flare nut comes in Use an appropriate wrench to avoid damaging the connection thread by overtightening the flare nut Flare nut tightening torque Flare nut for φ9 5 32 7 39 9N m 333 407kgf cm Flare nut for φ12 7 49 5 60 3N m 505 615kgf cm Flare nut for φ15 9 61 8 75 4N m 630 769kgf cm No 1 φ15 9 φ12 7 No 2 φ12 7 φ9 5 No 3 φ15 9 φ12 7 No 4 φ12 7 φ9 5 No 5 φ15 9 φ9 5 No 6 φ15 9 φ9 5 ...

Page 17: ... wrench 4 After two to three minutes close the gas stop valve and stop forced cooling operation 1 Forced operation 1 Turn the Operation Mode switch SW2 to COOL Heat pump only 2 Press the Forced Operation switch SW1 to begin forced cooling Press the Forced Operation switch SW1 again to stop forced cooling Gas stop valve Close Hexagonal wrench Liquid stop valve Valve caps Service PC board Operation ...

Page 18: ...crews The screws are packed with the terminal board 3 Pull the wire and make sure that it does not disconnect Then fix the wire in place with a wire stop Earth This air conditioner must be earthed For earthing follow the applicable local standard for electrical installations Safety breaker Earth leakage circuit breaker Outdoor unit 50Hz 220 240V Be sure to use the dedicated circuits To room B To r...

Page 19: ...s do not operate and enter standby mode according to the operation mode of the set indoor unit 1 2 Priority during high power operation If the indoor unit which is set for priority room setting is operating at high power the capabilities of other indoor units will be somewhat reduced Power supply gives priority to the indoor unit which is set for priority room setting 1 3 Quiet operation priority ...

Page 20: ... switch Once the settings are complete reset the power NOTE Install the removed jumper switch as described below This switch will be needed to later disable this setting COOL HEAT Mode Lock S15 only heat pump models Use the S15 connector to set the unit to only cool or heat Setting to only heat H short circuit pins 1 and 3 of the connector S15 Setting to only cool C short circuit pins 3 and 5 of t...

Page 21: ...4 are not displayed and for three rooms LED 4 is not displayed 2 If the outside air temperature is 5 C or less the wiring error check function will not operate 3 After wiring error check operation is completed LED indication will continue until ordinary operation starts This is normal 4 Follow the product diagnosis procedures Check the nameplate on the underside of the stop valve Wiring error chec...

Page 22: ...emperature adjustment Even when the air conditioner is not operating it consumes some electric power If the customer is not going to use the unit soon after it is installed turn off the breaker to avoid wasting electricity If additional refrigerant has been charged because of long piping list the amount added on the nameplate on the reverse side of the stop valve cover Cooling Heating Temperature ...

Page 23: ... 1210 HT 3P164392 4P M11B057B Two dimensional bar code is a code for manufacturing 00_CV_3P164392 4P fm Page 2 Tuesday October 30 2012 11 06 AM ...

Reviews: