C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
4-4
4.2.2
Connection of wire feeder
This section explains the connecting procedure of the wire feeder. Refer also to the instruction manual of
wire feeder.
T I P S
• When operating the welding power source by connecting to a robot, wiring for the wire feeder
needs to be changed. (
Wiring of Voltage Detection Cable at Base Metal Side)
1.
Connect the power cable for wire feeder (torch side) to the receptacle.
●
Firmly attach the power cable for torch side by turning the connector in the clockwise direction.
2.
Remove the cap of the socket of wire feeder and insert the control cable (10 cores) to the socket for
the wire feeder.
●
Fit the concave part of the connector and convex part of the socket for secure connection and tighten
the knurled screws in the clockwise direction.
●
When using an analog remote control (optional accessory), remove the cap of socket for analog remote
control and insert the control cable (6 cores).
Connection for wire feeder is complete. Procedure is followed by 4.2.3
• When not using an analog remote control (optional accessory), do not remove the cap
for the analog remote control.
Welding power source
Socket for the wire feeder
Socket for analog remote
control
Control cable of analog
remote control
Analog remote control
(Optional accessories)
Control cable for
wire feeder
Wire feeder
Receptacle
Cable fixture
Connector
Power cable for torch side