Dahua VTH1550CHW-2 User Manual Download Page 3

Important Safeguards and Warnings 

Please read the following safeguards and warnings carefully before using the product in order 

to avoid damages and losses. 

Note: 

 

Do not expose the device to lampblack, steam or dust. Otherwise it may cause fire or 

electric shock.   

 

Do  not  install  the  device  at  position  exposed  to  sunlight  or  in  high  temperature. 

Temperature rise in device may cause fire. 

 

Do not expose the device to humid environment. Otherwise it may cause fire.   

 

The  device must  be  installed  on  solid  and  flat  surface  in  order  to  guarantee  safety 

under load and earthquake. Otherwise, it may cause device to fall off or turnover. 

 

Do not place the device on carpet or quilt. 

 

Do  not  block  air  vent  of  the  device  or  ventilation  around  the  device.  Otherwise, 

temperature in device will rise and may cause fire. 

 

Do not place any object on the device.   

 

Do not disassemble the device without professional instruction. 

 

 

Warning:

 

 

Please use battery properly to avoid fire, explosion and other dangers.   

 

Please replace used battery with battery of the same type.   

 

Do not use power line other than the one specified. Please use it properly. Otherwise, 

it may cause fire or electric shock.     

 

Special Announcement 

 

This manual is for reference only.   

 

All the designs and software here are subject to change without prior written notice.   

 

owners.   

 

If there is any uncertainty or controversy, please refer to the final explanation of us.   

 

 

 

 

Summary of Contents for VTH1550CHW-2

Page 1: ...2 Wire VTH1550CHW 2 User s Manual V1 0 0 ...

Page 2: ...ection 8 2 3 Basic Config 8 2 3 1 Config 8 2 3 2 Result Verification 11 3 Product Function 12 3 1 Basic Function 12 3 1 1 Main Menu 12 3 1 2 Video Talk 13 3 1 3 Security 14 3 1 4 Info Search 16 3 1 5 System Settings 17 3 2 Unlock 21 3 3 Arm Disarm 21 3 4 2 4 Screen Calibration 22 Appendix 1 Technical Specification 23 Appendix 2 Toxic or Hazardous Materials or Elements 24 ...

Page 3: ...vice to fall off or turnover Do not place the device on carpet or quilt Do not block air vent of the device or ventilation around the device Otherwise temperature in device will rise and may cause fire Do not place any object on the device Do not disassemble the device without professional instruction Warning Please use battery properly to avoid fire explosion and other dangers Please replace used...

Page 4: ...m are connected via 2 pin cable for networking When visitor calls the resident via VTO resident may unlock door from any one master VTH or extension Figure 1 2 Villa Networking 2 1 VTO 3 VTH maximum analog converter are connected via 2 pin cable On analog converter use network cable to connect IPC for networking When visitor calls the resident via VTO resident may unlock door from any one master V...

Page 5: ... call to center Press this button to return to main menu Under calling status press this button to answer call During a call press this button to hang up Monitor VTO video During incoming call calling monitoring status press this button to unlock ...

Page 6: ...1 3 Rear Panel Figure 1 4 No Name Note 1 Alarm port 6 ch alarm in and 1 ch alarm out refer to label for details 2 2 Wire port 3 groups of 2 wire ports may connect to power VTH VTO or converter module ...

Page 7: ...ll immediately unplug network cable and cut power supply You may re plug in power after troubleshooting Project installation and debugging must be done by professionals Please do not open the device in case of failure and please contact after sales service 2 1 1Screw Component Name Diagram Quantity ST3x18 cross pan head tail self tapping screw nickel plating white 3 Chart 2 1 2 1 2Steps Step 1 Fix...

Page 8: ...ase see Ch 1 3 2 3 Basic Config After config it will have talk function 2 3 1Config Step 1 In Project Settings interface select System Settings Project Settings and enter password 002236 to enter Project Settings interface See Figure 2 2 ...

Page 9: ...ension and fill no In host IP fill in IP of master VTH so extension VTH will be automatically sync with host user config See Figure 2 3 Local extension Click OK Note VTH room no must match setup of VTH short no in WEB of VTO Figure 2 3 Local extension Step 4 Fill in master VTO name master VTO IP and set enable status to ON See Figure 2 4 ...

Page 10: ... 2 4 Step 5 Press and press Call button to go down Fill in extension VTO name extension VTO IP address Set enable status to ON You can add more than one extension VTO See Figure 2 5 Figure 2 5 Step 6 Click OK ...

Page 11: ...2 3 2Result Verification VTO call VTH via room no VTH pops up monitoring video and operation buttons You can accept hand up or unlock via VTH ...

Page 12: ...eo Talk Security Message and Settings Figure 3 1 Icon Name Note Network connection icon It means network connection is normal VTO not connected It means device does not connect to any VTO DND icon It means device enable DND do not disturb function Missed icon It means user has missed message ...

Page 13: ...101 is 1 1 101 press icon to call When the user being called answers the call user can have a bidirectional talk See Figure 3 2 Figure 3 2 Step 2 Click contact book icon user can call add edit and delete contacts Note If both the two indoor door stations are VTH CH models with front camera then you can perform a bidirectional visual talk 3 1 2 2 Monitor Click you can monitor unit VTO fence station...

Page 14: ... Figure 3 3 3 1 2 4 Management Center Click or press Emergency button and it is to call MGT center 3 1 3Security In main menu click Security to enter Security interface 3 1 3 1 Armed zone Step 1 Click interface shows current 8 ch area status including Area Type Current Status and Delay Time See Figure 3 4 ...

Page 15: ...word to enter area setting interface See Figure 3 5 Note The entry password is user password Default password is 123456 please see Ch 3 1 6 Figure 3 5 You can set bypass and delete for 4 6 channels to disable area for one time or long term ...

Page 16: ...3 Mode Setup Click set area alarm mode including Out mode In mode Sleep mode and Custom mode See Figure 3 6 Figure 3 6 Note Password to enter mode setup page is the user password and default password is 123456 Refer to Ch 3 1 6 3 1 4Info Search In main menu click Info Search to enter Info Search interface Click you can view delete and clear information published VTH receives information from the c...

Page 17: ...r system settings interface You can set VTH screen brightness incoming call ring talk time DND do not disturb time and etc 3 1 5 1 User Settings Click on you can set password ring talk DND local IPC clean touch ring SD card and snapshot plus restore default settings See Figure 3 8 ...

Page 18: ...assword unlock password arm password and anti hijack password See Figure 3 9 Figure 3 9 User password initially is 123456 Unlock password initially is null Arm password initially is 123456 Disarm password initially is 123456 Anti hijack password initially is 654321 ...

Page 19: ...screen brightness and screensaver via and Ring Click on Ring You can set call ring and alarm ring via and Talk Step 1 Click on Talk You can set ring call time monitor time record time and message time of VTO and VTH See Figure 3 10 Figure 3 10 Step 2 Click on to increase time click on to decrease time Unit is second Step 3 Click on OK DND ...

Page 20: ...Click on Save Step 3 In homepage click on talk to view added IPC video Clean Click on Clean to lock screen and now you can clean the screen Default Click on Default to restore system default settings Touch Ring Slide ON means touch sound is on OFF means touch sound is off 3 1 5 2 Project Settings Click on this function is for installer user only The entry password is 002236 ...

Page 21: ...sarm Disarm Status Press arm icon in homepage select one mode out in sleep and custom In pop up box input arm password default password is 123456 See Figure 3 12 Figure 3 12 If you select delay then system will enter armed status after the delay period If you select immediate arm then system will enter armed status when audio prompt ends Arm Status Press disarm icon in the lower right corner of ma...

Page 22: ...ill ask you to try again Note About hot to modify arm disarm password please refer to Ch 3 1 6 3 4 2 4 Screen Calibration The product is calibrated before shipped out from factory and if you want to calibrate the screen press unlock arm menu button to enter calibration interface Calibrate the screen according to the tips ...

Page 23: ...n loudspeaker Bidirectional Talk Support bidirectional talk Display Screen Dimension 7 inch TFT full real color Operation Mode Input Touch screen Alarm Alarm Input Support 6 ch local alarm inputs Alarm Output Support 1 ch local alarm output Network Ethernet 10M 100Mbps self adaptive Network Protocol TCP IP Specifications Power DC 24V Consumption Standby 1W working 7W Working Environment 10 55 10 9...

Page 24: ...zardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government sta...